1CPCLEAN(1)                           HUGIN                          CPCLEAN(1)
2
3
4

NAME

6       cpclean - Remove wrong control points by statistical methods
7

SYNOPSIS

9       cpclean [options] input.pto
10

DESCRIPTION

12       cpclean uses statistical methods to remove wrong control points.
13
14       Step 1 optimises all images pairs, calculates for each pair mean and
15       standard deviation and removes all control points with error bigger
16       than mean+n*sigma.
17
18       Step 2 optimises the whole panorama, calculates mean and standard
19       deviation for all control points and removes all control points with
20       error bigger than mean+n*sigma.
21

OPTIONS

23       --output|-o output.pto
24           Output Hugin PTO file. Default: '<filename>_clean.pto'.
25
26       --max-distance|-n num
27           distance factor for checking (default: 2)
28
29       --pairwise-checking|-p
30           do only pairwise optimisation (skip step 2)
31
32       --whole-pano-checking|-w
33           do optimise whole panorama (skip step 1)
34
35       --dont-optimize|-s
36           skip optimisation step when optimising the whole panorama
37
38       --check-line-cp|-l
39           also include line control points for calculation and filtering in
40           step 2
41
42       --help|-h
43           shows help
44

AUTHORS

46       Thomas Modes
47
48
49
50"Version: 2019.2.0"               2020-08-08                        CPCLEAN(1)
Impressum