1prtdiag(1M)             System Administration Commands             prtdiag(1M)
2
3
4

NAME

6       prtdiag - display system diagnostic information
7

SYNOPSIS

9       /usr/sbin/prtdiag [-v] [-l]
10
11

DESCRIPTION

13       prtdiag  displays  system  configuration  and diagnostic information on
14       sun4u, sun4v, and x86 systems.
15
16
17       The diagnostic information lists any  failed  field  replaceable  units
18       (FRUs) in the system.
19
20
21       The interface, output, and location in the directory hierarchy for prt‐
22       diag are uncommitted and subject to change in future releases.
23
24
25       prtdiag does not display diagnostic information and environmental  sta‐
26       tus  when  executed  on  the  Sun  Enterprise  10000  server.  See  the
27       /var/opt/SUNWssp/adm/${SUNW_HOSTNAME}/messages file on the system  ser‐
28       vice processor (SSP) to obtain such information for this server.
29

OPTIONS

31       The following options are supported:
32
33       -l    Log  output.  If  failures  or errors exist in the system, output
34             this information to syslogd(1M) only.
35
36
37       -v    Verbose mode. Displays the time of the most recent AC Power fail‐
38             ure,  and  the  most recent hardware fatal error information, and
39             (if applicable) environmental status. The  hardware  fatal  error
40             information  is  useful  to repair and manufacturing for detailed
41             diagnostics of FRUs.
42
43

EXIT STATUS

45       The following exit values are returned:
46
47       0    No failures or errors are detected in the system.
48
49
50       1    Failures or errors are detected in the system.
51
52
53       2    An internal prtdiag error occurred, for example, out of memory.
54
55

ATTRIBUTES

57       See attributes(5) for descriptions of the following attributes:
58
59
60
61
62       ┌─────────────────────────────┬─────────────────────────────┐
63       │      ATTRIBUTE TYPE         │      ATTRIBUTE VALUE        │
64       ├─────────────────────────────┼─────────────────────────────┤
65       │Availability                 │SUNWkvm                      │
66       ├─────────────────────────────┼─────────────────────────────┤
67       │Interface Stability          │Unstable*                    │
68       └─────────────────────────────┴─────────────────────────────┘
69
70
71       *The output is unstable.
72

SEE ALSO

74       modinfo(1M),   prtconf(1M),   psrinfo(1M),   sysdef(1M),   syslogd(1M),
75       attributes(5), openprom(7D)
76

NOTES

78       Not all diagnostic and system information is available on every Solaris
79       platform, and therefore cannot be displayed by prtdiag. On those  plat‐
80       forms, further information can be obtained from the System Controller.
81
82
83
84SunOS 5.11                        2 Sep 2008                       prtdiag(1M)