1PCP-VERIFY(1) General Commands Manual PCP-VERIFY(1)
2
3
4
6 pcp-verify - verify aspects of a PCP installation
7
9 pcp [pcp options] verify [-c/--containers] [-s/--secure] [-v/--verbose]
10
12 pcp-verify inspects various aspects of a PCP collector installation and
13 reports on whether it is configured correctly for certain modes of
14 operation.
15
16 By default, pcp-verify checks that PMCD is running and no agents are in
17 a failed state. These checks can be extended and refined using the
18 command line.
19
21 Additional options are available for changing the verification per‐
22 formed by pcp-verify.
23
24 -c/--containers verifies the collector installation for monitoring con‐
25 tainers.
26
27 -s/--secure verifies that the required components for encrypted commu‐
28 nication are in place.
29
30 -v/--verbose increase the verbosity, and report on each check as it is
31 made. In the absence of any issues found, pcp-verify operates
32 silently.
33
35 pcp-verify will exit with a non-zero status if it finds anything worth
36 reporting, otherwise it is silent and returns zero.
37
39 pcp(1) and PCPIntro(1).
40
41
42
43Performance Co-Pilot PCP PCP-VERIFY(1)