1DLM.CONF(5)                           dlm                          DLM.CONF(5)
2
3
4

NAME

6       dlm.conf - dlm_controld configuration file
7
8

SYNOPSIS

10       /etc/dlm/dlm.conf
11
12

DESCRIPTION

14       The  configuration  options in dlm.conf mirror the dlm_controld command
15       line options.  The config file additionally allows advanced fencing and
16       lockspace configuration that are not supported on the command line.
17
18

Command line equivalents

20       If  an  option is specified on the command line and in the config file,
21       the command line  setting  overrides  the  config  file  setting.   See
22       dlm_controld(8) for descriptions and dlm_controld -h for defaults.
23
24       Format:
25
26       key=val
27
28       Example:
29
30       log_debug=1
31       post_join_delay=10
32       protocol=tcp
33
34       Options:
35
36       log_debug
37       protocol
38       bind_all
39       mark
40       debug_logfile
41       enable_plock
42       plock_debug
43       plock_rate_limit
44       plock_ownership
45       drop_resources_time
46       drop_resources_count
47       drop_resources_age
48       post_join_delay
49       enable_fencing
50       enable_concurrent_fencing
51       enable_startup_fencing
52       enable_quorum_fencing
53       enable_quorum_lockspace
54       repeat_failed_fencing
55       enable_helper
56
57

Fencing

59       A fence device definition begins with a device line, followed by a num‐
60       ber of connect lines, one for each node connected to the device.
61
62       A blank line separates device definitions.
63
64       Devices are used in the order they are listed.
65
66       The device key word is followed by a unique dev_name, the agent program
67       to be used, and args, which are agent arguments specific to the device.
68
69       The connect key word is followed by the dev_name of the device section,
70       the node ID of the connected node in the format node=nodeid  and  args,
71       which are agent arguments specific to the node for the given device.
72
73       The  format  of  args is key=val on both device and connect lines, each
74       pair separated by a space, e.g. key1=val1 key2=val2 key3=val3.
75
76       Format:
77
78       device  dev_name agent [args]
79       connect dev_name node=nodeid [args]
80       connect dev_name node=nodeid [args]
81       connect dev_name node=nodeid [args]
82
83       Example:
84
85       device  foo fence_foo ipaddr=1.1.1.1 login=x password=y
86       connect foo node=1 port=1
87       connect foo node=2 port=2
88       connect foo node=3 port=3
89
90       device  bar fence_bar ipaddr=2.2.2.2 login=x password=y
91       connect bar node=1 port=1
92       connect bar node=2 port=2
93       connect bar node=3 port=3
94
95
96   Parallel devices
97       Some devices, like dual power or dual path, must all be turned  off  in
98       parallel  for  fencing to succeed.  To define multiple devices as being
99       parallel to each other, use the same base dev_name with different  suf‐
100       fixes and a colon separator between base name and suffix.
101
102       Format:
103
104       device  dev_name:1 agent [args]
105       connect dev_name:1 node=nodeid [args]
106       connect dev_name:1 node=nodeid [args]
107       connect dev_name:1 node=nodeid [args]
108
109       device  dev_name:2 agent [args]
110       connect dev_name:2 node=nodeid [args]
111       connect dev_name:2 node=nodeid [args]
112       connect dev_name:2 node=nodeid [args]
113
114       Example:
115
116       device  foo:1 fence_foo ipaddr=1.1.1.1 login=x password=y
117       connect foo:1 node=1 port=1
118       connect foo:2 node=2 port=2
119       connect foo:3 node=3 port=3
120
121       device  foo:2 fence_foo ipaddr=5.5.5.5 login=x password=y
122       connect foo:2 node=1 port=1
123       connect foo:2 node=2 port=2
124       connect foo:2 node=3 port=3
125
126
127   Unfencing
128       A  node  may sometimes need to "unfence" itself when starting.  The un‐
129       fencing command reverses the effect of  a  previous  fencing  operation
130       against  it.  An example would be fencing that disables a port on a SAN
131       switch.  A node could use unfencing to re-enable its switch  port  when
132       starting  up  after rebooting.  (Care must be taken to ensure it's safe
133       for a node to unfence itself.  A node often needs  to  be  cleanly  re‐
134       booted before unfencing itself.)
135
136       To  specify  that  a node should unfence itself for a given device, the
137       unfence line is added after the connect lines.
138
139       Format:
140
141       device  dev_name agent [args]
142       connect dev_name node=nodeid [args]
143       connect dev_name node=nodeid [args]
144       connect dev_name node=nodeid [args]
145       unfence dev_name
146
147       Example:
148
149       device  foo fence_foo ipaddr=1.1.1.1 login=x password=y
150       connect foo node=1 port=1
151       connect foo node=2 port=2
152       connect foo node=3 port=3
153       unfence foo
154
155
156   Simple devices
157       In some cases, a single fence device is used for all nodes, and it  re‐
158       quires no node-specific args.  This would typically be a "bridge" fence
159       device in which an agent is passing a fence request to another  subsys‐
160       tem  to handle.  (Note that a "node=nodeid" arg is always automatically
161       included in agent args, so a node-specific nodeid is always present  to
162       minimally identify the victim.)
163
164       In such a case, a simplified, single-line fence configuration is possi‐
165       ble, with format:
166
167       fence_all agent [args]
168
169       Example:
170
171       fence_all dlm_stonith
172
173       A fence_all configuration is not compatible with a fence device config‐
174       uration (above).
175
176       Unfencing can optionally be applied with:
177
178       fence_all agent [args]
179       unfence_all
180
181

Lockspace configuration

183       A lockspace definition begins with a lockspace line, followed by a num‐
184       ber of master lines.  A blank line separates lockspace definitions.
185
186       Format:
187
188       lockspace ls_name [ls_args]
189       master    ls_name node=nodeid [node_args]
190       master    ls_name node=nodeid [node_args]
191       master    ls_name node=nodeid [node_args]
192
193
194   Disabling resource directory
195       Lockspaces usually use a resource directory to keep track of which node
196       is  the  master  of each resource.  The dlm can operate without the re‐
197       source directory, though, by statically assigning the master of  a  re‐
198       source  using  a  hash  of  the resource name.  To enable, set the per-
199       lockspace nodir option to 1.
200
201       Example:
202
203       lockspace foo nodir=1
204
205
206   Lock-server configuration
207       The nodir setting can be combined with node weights to create a config‐
208       uration  where  select  node(s)  are the master of all resources/locks.
209       These master nodes can be viewed as "lock servers" for the other nodes.
210
211       Example of nodeid 1 as master of all resources:
212
213       lockspace foo nodir=1
214       master    foo node=1
215
216       Example of nodeid's 1 and 2 as masters of all resources:
217
218       lockspace foo nodir=1
219       master    foo node=1
220       master    foo node=2
221
222       Lock management will be partitioned among the available masters.  There
223       can be any number of masters defined.  The designated master nodes will
224       master all resources/locks (according to the resource name hash).  When
225       no  masters  are members of the lockspace, then the nodes revert to the
226       common fully-distributed configuration.  Recovery is faster, with  lit‐
227       tle disruption, when a non-master node joins/leaves.
228
229       There is no special mode in the dlm for this lock server configuration,
230       it's just a natural consequence of combining the  "nodir"  option  with
231       node  weights.   When  a lockspace has master nodes defined, the master
232       has a default weight of 1 and all non-master nodes have  weight  of  0.
233       An explicit non-zero weight can also be assigned to master nodes, e.g.
234
235       lockspace foo nodir=1
236       master    foo node=1 weight=2
237       master    foo node=2 weight=1
238
239       In  which case node 1 will master 2/3 of the total resources and node 2
240       will master the other 1/3.
241
242
243   Node configuration
244       Node configurations can be set by the node  keyword  followed  of  key-
245       value pairs.
246
247       Keys:
248
249       mark  The  mark  key  can be used to set a specific mark value which is
250       then used by the in-kernel DLM socket creation. This  can  be  used  to
251       match for DLM specfic packets for e.g. routing.
252
253       Example  of setting a per socket value for nodeid 1 and a mark value of
254       42:
255
256       node id=1 mark=42
257
258       For local nodes this value doesn't have any effect.
259
260