1SNMPD.INTERNAL(5) Net-SNMP SNMPD.INTERNAL(5)
2
3
4
6 snmpd.internal - internal configuration of the Net-SNMP agent
7
9 The snmpd.conf(5) man page defines the syntax and behaviour of the main
10 configuration directives that can be used to control the operation of
11 the Net-SNMP agent, and the management information it provides.
12
13 However there are several other configuration directives (many of
14 which, though not all, start with a leading underscore) that are recog‐
15 nised by the agent. These are typically used to retain configuration
16 across agent restarts, and are not intended for direct user access.
17 This man page list these directives, giving a brief indication of where
18 they are used. For full details - see the relevant source files. If
19 you can't follow that source, you probably shouldn't be fiddling with
20 these directives!
21
23 quit
24
26 VACM Configuration
27 vacmView / vacmGroup / vacmAccess
28 These directives are used to retain dynamically configured ac‐
29 cess control settings.
30
32 System Group
33 setSerialNo
34 This directive is used to implement the advisory lock object sn‐
35 mpSetSerialNo.
36
37 psyslocation / psyscontact / psysname
38 These directives are used to retain dynamically configured sys‐
39 tem settings. They will be overridden by the corresponding sys‐
40 Location, sysContact and sysName directives.
41
43 Notification Handling
44 pauthtrapenable
45 This directive is used to retain the dynamically configured set‐
46 ting of whether the agent should generate authenticationFailure
47 traps. It will be overridden by the corresponding authtrapen‐
48 able directive.
49
50 snmpNotify*Table
51
52 targetAddr / targetParams
53 These directives are used to retain dynamically configured noti‐
54 fication destination settings.
55
56 DisMan Event MIB
57 _mteE*Table, _mteOTable, _mteT*Table
58 These directives are used to retain dynamically configured
59 event, object and monitor trigger settings.
60
61 mteObjectsTable / mteTriggerTable
62 These directives are for compatibility with the previous dis‐
63 man/event-mib implementation.
64
65 DisMan Schedule MIB
66 _schedTable
67 This directive is used to retain dynamically configured sched‐
68 uled events.
69
71 Arbitrary Extension Commands
72 extend-sh
73
74 exec2 / sh2 / execFix2
75 These directives were defined by analogy with equivalent direc‐
76 tives in the previous ucd-snmp/extensible implementation. They
77 are deprecated, and should not be used.
78
80 /etc/snmp/snmpd.conf
81
83 snmpconf(1), snmpd.conf(5), snmp.conf(5), snmp_config(5), snmpd(8), EX‐
84 AMPLE.conf, netsnmp_config_api(3).
85
86
87
88V5.9.1 06 Dec 2005 SNMPD.INTERNAL(5)