1COROSYNC-QUORUMTOOL(8)      System Manager's Manual     COROSYNC-QUORUMTOOL(8)
2
3
4

NAME

6       corosync-quorumtool - Set and display quorum settings.
7

SYNOPSIS

9       corosync-quorumtool  [-s]  [-m]  [-l]  [-p]  [-v votes] [-n nodeid] [-e
10       expected] [-H] [-i] [-o <a|n|i>] [-a] [-f] [-h] [-V]
11

DESCRIPTION

13       Display the current state of quorum in the cluster and set vote  quorum
14       options.
15

OPTIONS

17       -s     show quorum status
18
19       -m     constantly monitor quorum status
20
21       -l     list nodes
22
23       -p     when used with -s or -l, generates machine parsable output
24
25       -v <votes>
26              change the number of votes for a node *
27
28       -n <nodeid>
29              optional nodeid of node for -v
30
31       -e <expected>
32              change expected votes for the cluster *
33
34       -H     show nodeids in hexadecimal rather than decimal
35
36       -i     show node IP addresses instead of the resolved name
37
38       -p     when used with -s or -l, generates machine parsable output
39
40       -o <a|n|i>
41              Orders  the  output  of  the  nodes list. By default or with -oa
42              nodes are  listed  in  IP  address  order:  as  they  come  from
43              corosync.  -on will order the nodes based on their name, and -oi
44              will order them based on their node ID.
45
46       -a     Show the name or IP address (see -i above) of all interfaces  in
47              use on the nodes, rather than just the first one.
48
49       -f     forcefully unregister a quorum device *DANGEROUS* *
50
51       -h (if no other argument)
52              show this help text
53
54       -V     show version and exit
55
56       *  Starred  items  only  work  if votequorum is the quorum provider for
57       corosync
58

EXIT STATUS

60       corosync-quorumtool may return one of several error codes if it encounā€
61       ters problems.
62
63       0      No problems occurred (quorate for -s operation).
64
65       1      Generic error code.
66
67       2      Not quorate (returned only for -s operation).
68

SEE ALSO

70       corosync_overview(7), votequorum_overview(3),
71

AUTHOR

73       Angus Salkeld
74
75                                  2019-02-14            COROSYNC-QUORUMTOOL(8)