1PMPARSETIMEWINDOW(3)       Library Functions Manual       PMPARSETIMEWINDOW(3)
2
3
4

NAME

6       pmParseTimeWindow, pmParseHighResTimeWindow - parse time window command
7       line arguments
8

C SYNOPSIS

10       #include <pcp/pmapi.h>
11
12       int pmParseTimeWindow(const char *swStart, const char *swEnd,
13               const char *swAlign, const char *swOffset,
14               const struct timeval *logStart, const struct timeval *logEnd,
15               struct timeval *rsltStart, struct timeval *rsltEnd,
16               struct timeval *rsltOffset, char **errMsg);
17       int pmParseHighResTimeWindow(const char *swStart, const char *swEnd,
18               const char *swAlign, const char *swOffset,
19               const struct timespec *logStart, const struct timespec *logEnd,
20               struct timespec *rsltStart, struct timespec *rsltEnd,
21               struct timespec *rsltOffset, char **errMsg);
22
23       cc ... -lpcp
24

DESCRIPTION

26       pmParseTimeWindow and pmParseHighResTimeWindow are designed to encapsu‐
27       late  the  interpretation of the -S, -T, -A and -O command line options
28       used by Performance Co-Pilot (PCP) applications to define a time window
29       of  interest.   The  time  window is defined by a start time and an end
30       time that constrains the time interval during which the PCP application
31       will  retrieve  and display performance metrics.  In the absence of the
32       -O and -A options to specify an initial sample  time  origin  and  time
33       alignment (see below), the PCP application will retrieve the first sam‐
34       ple at the start of the time window.
35
36       The syntax and meaning of the various argument formats  for  these  op‐
37       tions is described in PCPIntro(1).
38

USAGE

40       pmParseTimeWindow and pmParseHighResTimeWindow expect to be called with
41       the argument of the -S option as swStart, the argument of the -T option
42       as swEnd, the argument of the -A option as swAlign, and the argument of
43       the -O option as swOffset.  Any or all of these parameters may be  NULL
44       to indicate that the corresponding command line option was not present.
45
46       If the application is using a set of PCP archives as the source of per‐
47       formance metrics, you also need to supply the time of the first archive
48       entry  as  logStart,  and the time of the last archive entry as logEnd.
49       See pmGetArchiveLabel(3) and pmGetArchiveEnd(3) for how to obtain  val‐
50       ues for these times.
51
52       If  the  application is manipulating multiple concurrent archives, then
53       the caller must resolve how the default time window is  to  be  defined
54       (the  union of the time intervals in all archives is a likely interpre‐
55       tation).
56
57       If the application is using a live feed of performance  data,  logStart
58       should be the current time (but could be aligned on the next second for
59       example),  while  logEnd  should  have  its  tv_sec  component  set  to
60       PM_MAX_TIME_T.
61
62       The  rsltStart, rsltEnd and rsltOffset structures must be allocated be‐
63       fore calling pmParseTimeWindow or pmParseTimeHighResWindow.
64
65       You also need to set the current PCP reporting time zone  to  correctly
66       reflect the -z and -Z command line parameters before calling these rou‐
67       tines.  See pmUseZone(3) and friends for information  on  how  this  is
68       done.
69

DIAGNOSTICS

71       If  the conversion is successful, pmParseTimeWindow and pmParseHighRes‐
72       TimeWindow return 1 and fill in rsltStart, rsltEnd and rsltOffset  with
73       the start, end, and offset times for the time window defined by the in‐
74       put parameters.  The errMsg parameter is not changed  when  either  pm‐
75       ParseTimeWindow or pmParseHighResTimeWindow returns 1.
76
77       If  the conversion is successful, but the requested alignment could not
78       be performed (e.g. the set of PCP archives is too short) the  alignment
79       is  ignored,  rsltStart,  rsltEnd  and rsltOffset are filled in and pm‐
80       ParseTimeWindow and pmParseHighResTimeWindow return 0.  In  this  case,
81       errMsg  will point to a warning message in a dynamically allocated buf‐
82       fer.  The caller is responsible for releasing  the  buffer  by  calling
83       free(3).
84
85       If  the argument strings could not be parsed, pmParseTimeWindow and pm‐
86       ParseHighResTimeWindow return -1.  In this case, errMsg will  point  to
87       an  error message in a dynamically allocated buffer.  The caller is re‐
88       sponsible for releasing the buffer by calling free(3).
89

SEE ALSO

91       free(3), PMAPI(3), pmGetArchiveEnd(3), pmGetArchiveLabel(3),  pmNewCon‐
92       textZone(3), pmNewZone(3), pmParseInterval(3) and pmUseZone(3).
93