1DIGITEMP(1) General Commands Manual DIGITEMP(1)
2
3
4
6 digitemp - program to read from 1-wire temperature sensors.
7
9 digitemp [options]
10
12 DigiTemp uses the Dallas 1-wire bus to read temperatures from digital
13 sensors attached to a serial port adapter. It handles initializing the
14 bus, searching for attached devices, reading devices and custom log
15 strings. It supports the following temperature devices: DS1820,
16 DS18S20, DS18B20, DS1822
17
18 It also handles the DS2406 1-wire hub switches, and DS2422 and DS2423
19 counters.
20
21 DigiTemp uses either the DS9097 passive serial port adapter, or the
22 DS2480B based DS9097U adapter. 1-wire adapters from ibuttonlink.com,
23 such as the Link45 are also supported.
24
26 At least 1 action must be given, along with some optional arguments.
27 Actions are one (and only on) of the -w -t -a -w options
28
29 -h, -? Show summary of options.
30
31 -v Show verbose output.
32
33 -i Initialize .digitemprc file, search the bus for all supported
34 devices.
35
36 -I Initialize .digitemprc file, search the bus for all supported
37 devices, store devices in sorted serial # order.
38
39 -w Walk the full device tree and display the serial number and type
40 of all devices detected on the bus.
41
42 -s /dev/ttyS0
43 Set serial port to use. Make sure you have permission to access
44 this port. For USB operation pass USB instead of /dev/ttySX
45
46 -l /var/log/temperature
47 Send output to logfile, the output format is defined by the .B
48 -o command
49
50 -c digitemp.conf
51 Set digitemp configuration file. The default is .digitemprc in
52 the current directory.
53
54 -r 1000
55 Read delay in ms. This sets the amount of time to wait between
56 sending the temperature conversion command and reading the
57 result. The DS18S20 takes about 750mS to do the temperature con‐
58 version. Default is 1000mS (1 sec).
59
60 -t # Read sensor number #, the # depends on the order of the sensors
61 in the .digitemprc file.
62
63 -q Quiet output, no copyright banner.
64
65 -a Read all sensors.
66
67 -A Treat DS2438 as A/D converter, output raw voltages and currents.
68
69 -d 5 Delay between samples (in seconds).
70
71 -n 50 Number of times to repeat the command.
72
73 -O"counter format string"
74 See Counter Format below.
75
76 -o [1..3] ["output format string"]
77 See Temperature Format below.
78
79 -H"Humidity format string"
80 See Humidity Format below.
81
83 The temperature format can be either a numeric value, or a string. The
84 numeric values select pre-configured output formats:
85
86 1 = One line per sensor, time, C, F (default)
87 2 = One line per sample, elapsed time, temperature in C
88 3 = Same as #2, except temperature is in F
89
90 #2 and #3 have the data separated by tabs, suitable for import into a
91 spreadsheet or other graphing software.
92
93 The format string uses strftime tokens plus 5 special ones for Dig‐
94 iTemp:
95
96 %s for sensor #
97
98 %C for centigrade
99
100 %F for fahrenheit
101
102 %R to output the hex serial number
103
104 %N for seconds since Epoch.
105
106 The case of the token is important! The default format string is: "%b
107 %d %H:%M:%S Sensor %s C: %.2C F: %.2F" which gives you an output of:
108 May 24 21:25:43 Sensor 0 C: 23.66 F: 74.59
109
110 The DS2438 sensor can be used for a variety of things. It includes a
111 temperature sensor and A/D converter. DigiTemp defaults to using it as
112 a humidity sensor. The raw voltages and currents can be displayed by
113 passing the -A argument
114
115 When the -o2 or -o3 log options are used the attached DS2438's tempera‐
116 tures will be output without the humidity.
117
119 The counter format string is similar, adding these tokens:
120
121 %n is the counter #, which depends on its position in the .digitem‐
122 prc file
123
124 %C is the count in decimal.
125
127 The Humidity format string is the same as the temperature format string
128 with the addition of this format specifier:
129
130 %h is the humidity in 0-100%
131
133 This manual page was written by Jesús Roncero <jesus@roncero.org>, for
134 the Debian project (but may be used by others). Modifications by Brian
135 C. Lane <bcl@brianlane.com>
136
138 DigiTemp updates can be found on the http://www.digitemp.com website.
139
140
141
142 August 2008 DIGITEMP(1)