NAME

6       MSI2LMP - Converter for Materials Studio files to LAMMPS
7
8

SYNOPSIS

10       msi2lmp  [-help]  <ROOTNAME> [-class <I|1|II|2|O|0>] [-frc <path to frc
11       file>] [-print #] [-ignore] [-nocenter]  [-oldstyle]  [-shift  <x>  <y>
12       <z>]
13
14

DESCRIPTION

16       MSI2LMP is a tool bundled with LAMMPS to aide in the conversion of sim‐
17       ulation inputs from Biovia's Materials Studio  software  for  use  with
18       LAMMPS.   It  is a standalone program that generates a LAMMPS data file
19       based on the information in an MS .car file (atom coordinates), an .mdf
20       file (molecular topology and atom types) and an .frc (forcefield param‐
21       eters) file.  The .car and .mdf files are specific to a molecular  sys‐
22       tem  while  the  .frc  file is specific to a forcefield (variant).  The
23       only coherency needed between .frc and .car/.mdf  files  are  the  atom
24       types.
25

OPTIONS

27       -h, -help,
28              Print detailed help message to the screen and stop.
29
30       <ROOTNAME>
31              This  has  to be the first argument and is a mandatory argument.
32              It defines the root of the file names; i.e. for a <ROOTNAME>  of
33              benzene,  you  have to provide the files 'benzene.car' and 'ben‐
34              zene.mdf' in the current working directory.  msi2lmp  will  then
35              read  and  process  those  files according to its remaining set‐
36              tings.  All other settings are optional  and  have  defaults  as
37              listed.
38
39       -c <I,1,II,2,O,0>, -class <I,1,II,2,O,0>
40              The -c or -class option selects the force field class, i.e which
41              pair styles and bond styles and so on are required in the LAMMPS
42              input  file.   Class  I  or  class 1 uses similar combination of
43              functional forms as Amber and Charmm force field and support the
44              force  fields  cvff and clayff.  Class II or class 2 corresponds
45              to the more complex force fields COMPASS and pcff.  Class  O  or
46              class  0 finally is an experimental and incomplete extension and
47              supports generating output for OPLS-AA
48
49       -f <ffname>, -frc <ffname>
50              The -c or -frc option allows the selection of  the  force  field
51              parameter  file  Valid names for <ffname> with this distribution
52              are: cvff, clayff, cvff_aug, pcff, compass_published, cff91, and
53              oplsaa. If the argument is a pathname, i.e. it starts with a '.'
54              or a '/', then this absolute path is  used  to  read  the  force
55              field,  otherwise  msi2lmp will look in the folder pointed to by
56              the environment variable $MSI2LMP_LIBRARY. If  the  variable  is
57              not  set, then it will look in the current directory. The exten‐
58              sion '.frc' is appended, if missing.  Default is to look for the
59              cvff.frc force field file.
60
61       -p <loglevel>, -print <loglevel>,
62              Selects the amount of information messages about the progress of
63              the conversion printed to the screen.  <loglevel> can be a  num‐
64              ber from 0 (silent except for errors) to 3 (very detailed).
65
66       -i, -ignore,
67              Ignore  errors  about missing parameters and use 0.0 for the re‐
68              spective force constants making these no-ops. Is correct  to  be
69              used  for a few molecules and settings, but often an indication,
70              that either the atom type assignment have errors, or  the  force
71              field file is missing entries.
72
73       -n, -nocenter,
74              Do  not  center  the  box around the (geometrical) center of the
75              atoms, but around the origin. Default is to recenter.
76
77       -o, -oldstyle,
78              Write out a data file without style hint comments to be compati‐
79              ble with old LAMMPS versions. Default is to write out those com‐
80              ments.
81
82       -s <x> <y> <z>, -shift <x> <y> <z>,
83              Shift the entire system (box and coordinates) by a  vector  (de‐
84              fault: 0.0 0.0 0.0).
85
86
87
88       EXAMPLES
89
90              msi2lmp benzene -c 2 -p 1 -f ../frc_files/pcff.frc
91
92              msi2lmp benzene-class1 -c I
93
94              msi2lmp decane -c 0 -f oplsaa
95
96
97
99       © 2003--2022 Sandia Corporation
100
101       This package is free software; you can redistribute it and/or modify it
102       under the terms of the GNU General Public License  version  2  as  pub‐
103       lished by the Free Software Foundation.
104
105       This  package  is  distributed  in the hope that it will be useful, but
106       WITHOUT ANY  WARRANTY;  without  even  the  implied  warranty  of  MER‐
107       CHANTABILITY  or FITNESS FOR A PARTICULAR PURPOSE.  See the GNU General
108       Public License for more details.
109
110
111
112
1132023-03-10                          v3.9.10                         MSI2LMP(1)
Impressum