1HYLAFAX-INFO(5F)                                              HYLAFAX-INFO(5F)
2
3
4

NAME

6       info - remote device capability database
7

DESCRIPTION

9       The  info  subdirectory  in the HylaFAX spooling area holds information
10       about the capabilities and status of devices  that  have  been  called.
11       One  file  exists  for  each device, with the filename created from the
12       remote device's fully-qualified phone  number.   Files  have  a  simple
13       ASCII format.  Each line is of the form
14            [&]tag: value
15       where  a  tag  identifies  a capability and a value is either a string,
16       number, or boolean value.  An optional ``&'' at the front of  the  line
17       indicates that the tag's value is locked down and should not be updated
18       by the server.  This facility is useful for restricting  the  capabili‐
19       ties used with a particular machine.
20
21       The following items are recorded:
22              Tag                   Type       Description
23              calledBefore          boolean    device has previously answered at this number
24              dialFailures          number     count of consecutive failed dial operations
25              hasV34Trouble         boolean    there is difficulty sending to this destination with V.34
26              hasV17Trouble         boolean    there is difficulty sending to this destination with V.17
27              lastDialFailure       string     reason for last failed dial operation
28              lastSendFailure       string     reason for last failed send attempt
29              maxPageWidth          number     maximum page width in pixels in normal resolution
30              maxPageLength         number     maximum page length in millimeters
31              maxSignallingRate     string     maximum signalling rate (bits/sec) to use
32              minScanlineTime       string     minimum scanline time
33              pagerMaxMsgLength     number     length of longest allowed text message
34              pagerPassword         string     password string send to service provider
35              pagerSetupCmds        string     commands for setting up modem for a specific service provider
36              pagerTTYParity        string     parity & # bits configuration for IXO/TAP communication
37              pageSource            string     parameter to tell the paging central who we are
38              pagingProtocol        string     protocol (IXO or UCP) for this provider
39              remoteCSI             string     remote device Called Subscriber Identification
40              remoteNSF             string     remote equipment Non-Standard Facilities information
41              remoteDIS             string     remote Digital Identification Signal: capabilities
42              sendFailures          number     count of consecutive failed send attempts
43              dataSent              number     units of data sent to the destination in the last session
44              dataSent1             number     units of data sent to the destination in the session previous to the last
45              dataSent2             number     units of data sent to the destination in the session previous, previous to the last
46              dataMissed            number     units of data sent to the destination which were missed or corrupt in the last session
47              dataMissed1           number     units of data sent to the destination which were missed or corrupt in session previous to the last
48              dataMissed2           number     units of data sent to the destination which were missed or corrupt in session previous, previous to the last
49              senderConfusesPIN     boolean    this caller does not return to Phase B and resend the same page after PIN
50              senderConfusesRTN     boolean    this caller does not return to Phase B and resend the same page after RTN
51              senderDataSent        number     units of data sent by the sender in the last session
52              senderDataSent1       number     units of data sent by the sender in the session previous to the last
53              senderDataSent2       number     units of data sent by the sender in the session previous, previous to the last
54              senderDataMissed      number     units of data sent by the sender which were missed or corrupt in the last session
55              senderDataMissed1     number     units of data sent by the sender which were missed or corrupt in session previous to the last
56              senderDataMissed2     number     units of data sent by the sender which were missed or corrupt in session previous, previous to the last
57              senderHasV17Trouble   boolean    there is difficulty receiving from this caller with V.17
58              senderSkipsV29        boolean    this caller does not use V.29 in the presence of V.17
59              supportsBatching      boolean    accepts batching protocol
60              supportsHighRes       boolean    accepts 196 line/inch images (obsolete)
61              supportsVRes          number     vertical resolution support bitmask
62              supports2DEncoding    boolean    accepts Group 3 2D encoding
63              supportsMMR           boolean    accepts Group 4 encoding
64              supportsPostScript    boolean    accepts Adobe POSTSCRIPT transfer protocol
65
66       The  HylaFAX  scheduler,  faxq(8C), uses the information stored in this
67       directory when deciding if a call should be placed and  when  preparing
68       documents  for  transmission.   If  a  remote device's capabilities are
69       known,  then  document  preparation  is  constrained  and/or  optimized
70       according to the capabilities.  Otherwise, documents are prepared with‐
71       out regard for the remote device's capabilities  and  if  a  capability
72       mismatch is encountered the session is terminated and the documents are
73       reformatted using the newly discovered capabilities.
74
75       The calledBefore item is used by faxsend to decide whether  or  not  to
76       redial  a  phone number when encountering certain errors.  For example,
77       if a dialing command results in a ``NO CARRIER'' result, then the  num‐
78       ber  will  not  be retried unless the number has previously been dialed
79       successfully.
80
81       The minScanlineTime item indicates the minimum scanline time  parameter
82       used  for  facsimile  transmissions.   Acceptable  values are: ``0ms'',
83       ``5ms'',    ``10ms/5ms'',    ``10ms'',     ``20ms/10ms'',     ``20ms'',
84       ``40ms/20ms'', and ``40ms''.  (Values of the form X/Y mean to use X for
85       98 lpi images and Y for 196 lpi images.)
86
87       The pagerTTYParity item specifies the communication parameters  to  use
88       when  communicating with the IXO/TAP service provider.  Acceptable val‐
89       ues are: ``even'' (7 bits, even parity), ``odd'' (7 bits, odd  parity),
90       and  ``none''  (8  bits,  no  parity).   If  nothing  is specified then
91       ``even'' is used per the standard.
92
93       The pagerMaxMsgLength, pagerPassword, and pagerTTYParity items  can  be
94       setup  according  to the requirements of a pager service provider; they
95       typically are locked down so that their  values  are  not  lost  during
96       updates.
97
98       The pagerSetupCmds can be used to define AT commands for setting up the
99       modem for a specific service provider.  This value overwrites the  set‐
100       tings defined in hylafax-config(5F).
101
102       The  pageSource parameter can be used to tell the paging central who we
103       are.  It usually contains a SMS answerable mobile number.  It  is  only
104       used for the UCP part of sendpage(8C).  Note:  This parameter should be
105       used from user-land sendpage(1) and will be removed later.
106
107       The pagingProtocol defines which protocol, UCP or IXO, should  be  used
108       to  send  the  message to the service provider. It defaults to ``ixo'';
109       for UCP set ``ucp''.
110

NOTES

112       faxsend, pagesend, and faxq automatically create and update entries  in
113       the info directory, as required.
114
115       The  data  in  this  directory is simply a cache of remote capabilities
116       and, except for locked down items, can be safely purged  at  any  time.
117       The  faxcron(8C)  script,  for  example,  periodically  purges unlocked
118       entries in this directory that have not been accessed in 30 days.
119
120       When the first batching attempt fails then supportsBatching is  set  to
121       false.   It  must be manually altered in order to re-enable batching to
122       the destination.
123
124       Restricting the capabilities used with a particular machine to a  value
125       other than those that are mandatory can cause documents to be sent out‐
126       side of an acceptable range for the receiver.
127

SEE ALSO

129       faxcron(8C), faxq(8C), faxsend(8C), pagesend(8C), hylafax-config(5F)