1MODBUS_CONNECT(3) libmodbus Manual MODBUS_CONNECT(3)
2
3
4
6 modbus_connect - establish a Modbus connection
7
9 int modbus_connect(modbus_t *ctx);
10
12 The modbus_connect() function shall establish a connection to a Modbus
13 server, a network or a bus using the context information of libmodbus
14 context given in argument.
15
17 The function shall return 0 if successful. Otherwise it shall return -1
18 and set errno to one of the values defined by the system calls of the
19 underlying platform.
20
22 modbus_t *ctx;
23
24 ctx = modbus_new_tcp("127.0.0.1", 502);
25 if (modbus_connect(ctx) == -1) {
26 fprintf(stderr, "Connection failed: %s\n", modbus_strerror(errno));
27 modbus_free(ctx);
28 return -1;
29 }
30
32 modbus_close(3)
33
35 The libmodbus documentation was written by Stéphane Raimbault
36 <stephane.raimbault@gmail.com>
37
38
39
40libmodbus v3.1.6 01/19/2023 MODBUS_CONNECT(3)