NAME

6       ipmi-oem - IPMI OEM utility
7

SYNOPSIS

9       ipmi-oem [OPTION...] <OEMID> <OEMCOMMAND> [OEMOPTION...]
10

DESCRIPTION

12       Ipmi-oem  is used to execute OEM specific IPMI commands. It is intended
13       to provide a better user  interface  for  OEM  specific  IPMI  commands
14       rather than using ipmi-raw(8).
15
16       Please see SUPPORTED OEM IDS and COMMANDS below for a list of supported
17       OEM specific IPMI commands. A list of supported OEM  specific  commands
18       may also be generated using the --list option.
19
20       There  are  no  guarantees that the below OEM commands will work on any
21       particular motherboard. OEM extensions may or may not exist on particu‐
22       lar  hardware  revisions and/or firmware revisions of motherboards. The
23       extensions may or may not function for other lines of motherboards from
24       the same manufacturer.
25
26       Listed  below  are general IPMI options, tool specific options, trouble
27       shooting  information,  workaround  information,  examples,  and  known
28       issues. For a general introduction to FreeIPMI please see freeipmi(7).
29

GENERAL OPTIONS

31       The following options are general options for configuring IPMI communi‐
32       cation and executing general tool commands.
33
34       -D IPMIDRIVER, --driver-type=IPMIDRIVER
35              Specify the driver type to use instead of doing an  auto  selec‐
36              tion.   The  currently  available  outofband drivers are LAN and
37              LAN_2_0, which perform IPMI 1.5 and IPMI 2.0  respectively.  The
38              currently  available inband drivers are KCS, SSIF, OPENIPMI, and
39              SUNBMC.
40
41       --disable-auto-probe
42              Do not probe in-band IPMI devices for default settings.
43
44       --driver-address=DRIVER-ADDRESS
45              Specify the in-band driver address to be  used  instead  of  the
46              probed  value. DRIVER-ADDRESS should be prefixed with "0x" for a
47              hex value and '0' for an octal value.
48
49       --driver-device=DEVICE
50              Specify the in-band driver device path to be used instead of the
51              probed path.
52
53       --register-spacing=REGISTER-SPACING
54              Specify  the  in-band  driver  register  spacing  instead of the
55              probed value. Argument is in bytes (i.e. 32bit register  spacing
56              = 4)
57
58       --target-channel-number=CHANNEL-NUMBER
59              Specify  the  in-band  driver target channel number to send IPMI
60              requests to.
61
62       --target-slave-address=SLAVE-ADDRESS
63              Specify the in-band driver target  slave  number  to  send  IPMI
64              requests to.
65
66       -h      IPMIHOST1,IPMIHOST2,...,      --hostname=IPMIHOST1[:PORT],IPMI‐
67       HOST2[:PORT],...
68              Specify the remote host(s) to communicate with.  Multiple  host‐
69              names  may  be separated by comma or may be specified in a range
70              format; see HOSTRANGED SUPPORT below. An optional  port  can  be
71              specified with each host, which may be useful in port forwarding
72              or similar situations.
73
74       -u USERNAME, --username=USERNAME
75              Specify the username to use when authenticating with the  remote
76              host.   If  not  specified,  a null (i.e. anonymous) username is
77              assumed. The required user privilege will depend on the oem com‐
78              mands executed.
79
80       -p PASSWORD, --password=PASSWORD
81              Specify the password to use when authenticationg with the remote
82              host.  If not specified, a null  password  is  assumed.  Maximum
83              password length is 16 for IPMI 1.5 and 20 for IPMI 2.0.
84
85       -P, --password-prompt
86              Prompt  for  password  to  avoid  possibility  of  listing it in
87              process lists.
88
89       -k K_G, --k-g=K_G
90              Specify the K_g BMC key to  use  when  authenticating  with  the
91              remote  host  for  IPMI  2.0.  If  not  specified, a null key is
92              assumed. To input the key in hexadecimal form, prefix the string
93              with  '0x'.  E.g.,  the key 'abc' can be entered with the either
94              the string 'abc' or the string '0x616263'
95
96       -K, --k-g-prompt
97              Prompt for k-g to avoid possibility of  listing  it  in  process
98              lists.
99
100       --session-timeout=MILLISECONDS
101              Specify  the  session timeout in milliseconds. Defaults to 20000
102              milliseconds (20 seconds) if not specified.
103
104       --retransmission-timeout=MILLISECONDS
105              Specify  the  packet  retransmission  timeout  in  milliseconds.
106              Defaults  to  1000 milliseconds (1 second) if not specified. The
107              retransmission timeout cannot be larger than the  session  time‐
108              out.
109
110       -a AUTHENTICATION-TYPE, --authentication-type=AUTHENTICATION-TYPE
111              Specify  the  IPMI 1.5 authentication type to use. The currently
112              available authentication types are NONE,  STRAIGHT_PASSWORD_KEY,
113              MD2, and MD5. Defaults to MD5 if not specified.
114
115       -I CIPHER-SUITE-ID, --cipher-suite-id=CIPHER-SUITE-ID
116              Specify the IPMI 2.0 cipher suite ID to use. The Cipher Suite ID
117              identifies a set of authentication, integrity, and confidential‐
118              ity  algorithms to use for IPMI 2.0 communication. The authenti‐
119              cation algorithm identifies the algorithm  to  use  for  session
120              setup,  the  integrity algorithm identifies the algorithm to use
121              for session packet signatures, and the confidentiality algorithm
122              identifies the algorithm to use for payload encryption. Defaults
123              to cipher suite ID 3 if  not  specified.  The  following  cipher
124              suite ids are currently supported:
125
126              0 - Authentication Algorithm = None; Integrity Algorithm = None;
127              Confidentiality Algorithm = None
128
129              1 - Authentication Algorithm = HMAC-SHA1; Integrity Algorithm  =
130              None; Confidentiality Algorithm = None
131
132              2  - Authentication Algorithm = HMAC-SHA1; Integrity Algorithm =
133              HMAC-SHA1-96; Confidentiality Algorithm = None
134
135              3 - Authentication Algorithm = HMAC-SHA1; Integrity Algorithm  =
136              HMAC-SHA1-96; Confidentiality Algorithm = AES-CBC-128
137
138              6  -  Authentication Algorithm = HMAC-MD5; Integrity Algorithm =
139              None; Confidentiality Algorithm = None
140
141              7 - Authentication Algorithm = HMAC-MD5; Integrity  Algorithm  =
142              HMAC-MD5-128; Confidentiality Algorithm = None
143
144              8  -  Authentication Algorithm = HMAC-MD5; Integrity Algorithm =
145              HMAC-MD5-128; Confidentiality Algorithm = AES-CBC-128
146
147              11 - Authentication Algorithm = HMAC-MD5; Integrity Algorithm  =
148              MD5-128; Confidentiality Algorithm = None
149
150              12  - Authentication Algorithm = HMAC-MD5; Integrity Algorithm =
151              MD5-128; Confidentiality Algorithm = AES-CBC-128
152
153              15 - Authentication Algorithm = HMAC-SHA256; Integrity Algorithm
154              = None; Confidentiality Algorithm = None
155
156              16 - Authentication Algorithm = HMAC-SHA256; Integrity Algorithm
157              = HMAC_SHA256_128; Confidentiality Algorithm = None
158
159              17 - Authentication Algorithm = HMAC-SHA256; Integrity Algorithm
160              = HMAC_SHA256_128; Confidentiality Algorithm = AES-CBC-128
161
162       -l PRIVILEGE-LEVEL, --privilege-level=PRIVILEGE-LEVEL
163              Specify  the privilege level to be used. The currently available
164              privilege levels are USER,  OPERATOR,  and  ADMIN.  Defaults  to
165              ADMIN if not specified.
166
167       --config-file=FILE
168              Specify an alternate configuration file.
169
170       -W WORKAROUNDS, --workaround-flags=WORKAROUNDS
171              Specify  workarounds to vendor compliance issues. Multiple work‐
172              arounds can be specified separated by commas. A special  command
173              line flag of "none", will indicate no workarounds (may be useful
174              for overriding configured defaults). See WORKAROUNDS below for a
175              list of available workarounds.
176
177       --debug
178              Turn on debugging.
179
180       -?, --help
181              Output a help list and exit.
182
183       --usage
184              Output a usage message and exit.
185
186       -V, --version
187              Output the program version and exit.
188

SDR CACHE OPTIONS

190       This tool requires access to the sensor data repository (SDR) cache for
191       general operation. By default, SDR data will be downloaded  and  cached
192       on the local machine. The following options apply to the SDR cache.
193
194       -f, --flush-cache
195              Flush  a  cached  version  of  the  sensor data repository (SDR)
196              cache. The SDR is typically cached for faster subsequent access.
197              However,  it  may need to be flushed and re-generated if the SDR
198              has been updated on a system.
199
200       -Q, --quiet-cache
201              Do not output information about cache creation/deletion. May  be
202              useful in scripting.
203
204       --sdr-cache-recreate
205              If the SDR cache is out of date or invalid, automatically recre‐
206              ate the sensor data repository (SDR) cache. This option  may  be
207              useful for scripting purposes.
208
209       --sdr-cache-file=FILE
210              Specify a specific sensor data repository (SDR) cache file to be
211              stored or read from. If this option is used when multiple  hosts
212              are  specified,  the  same  SDR  cache file will be used for all
213              hosts.
214
215       --sdr-cache-directory=DIRECTORY
216              Specify an alternate directory for sensor data repository  (SDR)
217              caches to be stored or read from. Defaults to the home directory
218              if not specified.
219

HOSTRANGED OPTIONS

221       The following options manipulate hostranged output. See HOSTRANGED SUP‐
222       PORT below for additional information on hostranges.
223
224       -B, --buffer-output
225              Buffer  hostranged output. For each node, buffer standard output
226              until the node has completed its IPMI operation. When specifying
227              this  option, data may appear to output slower to the user since
228              the the entire IPMI operation must complete before any data  can
229              be output.  See HOSTRANGED SUPPORT below for additional informa‐
230              tion.
231
232       -C, --consolidate-output
233              Consolidate hostranged output. The complete standard output from
234              every  node  specified  will  be consolidated so that nodes with
235              identical output are not output twice. A header will list  those
236              nodes  with  the consolidated output. When this option is speci‐
237              fied, no output can be seen until the  IPMI  operations  to  all
238              nodes  has  completed.  If  the  user  breaks out of the program
239              early, all currently consolidated output  will  be  dumped.  See
240              HOSTRANGED SUPPORT below for additional information.
241
242       -F NUM, --fanout=NUM
243              Specify  multiple  host  fanout.  A "sliding window" (or fanout)
244              algorithm is used for parallel IPMI communication so that slower
245              nodes or timed out nodes will not impede parallel communication.
246              The maximum number of threads available at the same time is lim‐
247              ited by the fanout. The default is 64.
248
249       -E, --eliminate
250              Eliminate  hosts  determined  as undetected by ipmidetect.  This
251              attempts to remove the common issue of hostranged execution tim‐
252              ing  out  due  to  several nodes being removed from service in a
253              large cluster. The ipmidetectd daemon must  be  running  on  the
254              node executing the command.
255
256       --always-prefix
257              Always prefix output, even if only one host is specified or com‐
258              municating in-band. This option is primarily useful for  script‐
259              ing  purposes.  Option  will be ignored if specified with the -C
260              option.
261

IPMI-OEM OPTIONS

263       The following options are specific to Ipmi-oem.
264
265       -L, --list
266              List supported OEM IDs and Commands.
267
268       -v, --verbose
269              Output verbose information. Additional  output  will  depend  on
270              specific OEM ID and OEM COMMANDS specified.
271

SUPPORTED OEM IDS and COMMANDS

273       The currently supported OEM IDs and COMMANDs are listed below. The spe‐
274       cial OEM ID of list may be passed into the list all supported  OEM  IDs
275       and  Commands. The special OEM command list may be passed to any OEM ID
276       to list commands supported by that OEM ID.
277
278       Dell
279
280              get-system-info KEY
281                     This OEM command  can  retrieve  the  motherboard  system
282                     information.    Valid  keys  are  guid,  asset-tag,  ser‐
283                     vice-tag,    chassis-service-tag,    chassis-related-ser‐
284                     vice-tag,  board-revision, platform-model-name, slot-num‐
285                     ber,   system-revision,    idrac-info,    idrac-ipv4-url,
286                     idrac-gui-webserver-control, cmc-ipv4-url, cmc-ipv6-info,
287                     cmc-ipv6-url, mac-addresses. Command confirmed to work on
288                     Dell Poweredge 2900, 2950, R610, R710, M600, M610, M610X,
289                     M910, and R905. However,  individual  system  information
290                     options may not be readable or available on every system.
291
292              get-nic-selection
293                     This OEM command will determine the current NIC selection
294                     for IPMI as dedicated,  shared,  shared  w/  failover  to
295                     NIC2,  or  shared w/ failover to all. Dedicated indicates
296                     IPMI is only available on an expansion card, shared indi‐
297                     cates  IPMI  is  available on NIC1, shared w/ failover to
298                     NIC2 indicates IPMI is available on NIC1 w/  failover  to
299                     NIC2  on  NIC1's  failure,  and shared w/ failover to all
300                     indicates IPMI is available on NIC1 w/  failover  to  all
301                     other NICs in the event of NIC failure. Command confirmed
302                     to work on Dell Poweredge 2900,  2950,  R610,  R710,  and
303                     R905.
304
305              set-nic-section                                            dedi‐
306              cated|shared|shared_failover_nic2|shared_failover_all
307                     This OEM command will set the current  NIC  selection  to
308                     dedicated,      shared,      shared_failover_nic2,     or
309                     shared_failover_all.  (See  get-nic-selection  above  for
310                     description  on  inputs.)  On  older  Poweredge  systems,
311                     shared_failover_nic2 may have  been  documented  as  just
312                     failover.  Command  confirmed  to  work on Dell Poweredge
313                     2900, 2950, R610, R710, and R905.
314
315              get-active-lom-status
316                     This OEM command will get the current NIC being used  for
317                     out of band management. Command confirmed to work on Dell
318                     Poweredge R610 and R710 (Dell 11G Poweredge systems).
319
320              get-ssh-config
321                     This OEM command will get the current  SSH  configuration
322                     on  the IPMI card. Command confirmed to work on Dell Pow‐
323                     eredge R610 and R710 (Dell 11G Poweredge systems).
324
325              set-ssh-config KEY=VALUE ...
326                     This OEM command will set the current  SSH  configuration
327                     on  the  IPMI  card.  The  possible  keys  and values are
328                     ssh=enable|disable,  idletimeout=seconds,  and   portnum‐
329                     ber=num. Multiple key=value pairs may be specified. If no
330                     key=value pairs are specifed, available pairs are output.
331                     Some  fields  may be read-only on specific Poweredge sys‐
332                     tems. Command confirmed to work on  Dell  Poweredge  R610
333                     and R710 (Dell 11G Poweredge systems).
334
335              get-telnet-config
336                     This  OEM  command will get the current telnet configura‐
337                     tion on the IPMI card. Command confirmed to work on  Dell
338                     Poweredge R610 and R710 (Dell 11G Poweredge systems).
339
340              set-telnet-config KEY=VALUE ...
341                     This  OEM  command will set the current Telnet configura‐
342                     tion on the IPMI card. The possible keys and  values  are
343                     telnet=enable|disable,  sessiontimeout=seconds,  portnum‐
344                     ber=num,  and  7fls=enable|disable.  Multiple   key=value
345                     pairs  may  be  specified.   If  no  key=value  pairs are
346                     specifed, available pairs are output. Some fields may  be
347                     read-only  on  specific  Poweredge  systems. Command con‐
348                     firmed to work on Dell Poweredge R610 and R710 (Dell  11G
349                     Poweredge systems).
350
351              get-web-server-config
352                     This OEM command will get the current web server configu‐
353                     ration on the IPMI card. Command  confirmed  to  work  on
354                     Dell  Poweredge  R610  and  R710 (Dell 11G Poweredge sys‐
355                     tems).
356
357              set-web-server-config KEY=VALUE ...
358                     This OEM command will set the current Web Server configu‐
359                     ration on the IPMI card. The possible keys and values are
360                     webserver=enable|disable,  sessiontimeout=seconds,  http‐
361                     portnumber=num,    and    httpsportnumber=num.   Multiple
362                     key=value pairs may be specified. If no  key=value  pairs
363                     are specifed, available pairs are output. Some fields may
364                     be read-only on specific Poweredge systems. Command  con‐
365                     firmed  to work on Dell Poweredge R610 and R710 (Dell 11G
366                     Poweredge systems).
367
368              get-active-directory-config
369                     This OEM command will get the  current  active  directory
370                     configuration on the IPMI card. Command confirmed to work
371                     on Dell Poweredge R610 and R710 (Dell 11G Poweredge  sys‐
372                     tems).
373
374              set-active-directory-config
375                     This OEM command will set the current Web Server configu‐
376                     ration on the IPMI card. The possible keys and values are
377                     activedirectory=enable|disable,          timeout=seconds,
378                     type=extended|standard, sso=enable|disable, and  certifi‐
379                     catevalidation=enable|disable.  If no key=value pairs are
380                     specifed, available pairs are output. Some fields may  be
381                     read-only  on  specific  Poweredge  systems. Command con‐
382                     firmed to work on Dell Poweredge R610 and R710 (Dell  11G
383                     Poweredge systems).
384
385              reset-to-defaults
386                     This OEM command will reset the BMC configuration back to
387                     default values. The command will spin until the reset  is
388                     confirmed  to  be  complete. Command confirmed to work on
389                     Dell Poweredge R610 and R710  (Dell  11G  Poweredge  sys‐
390                     tems).
391
392              get-power-consumption-data
393                     This  OEM  command  can  retrieve power consumption data.
394                     Command confirmed to work on Dell Poweredge  R610,  R710,
395                     R905, M610, M610x, and M910.
396
397              reset-power-consumption-data cumulative|peak
398                     This  OEM  command can reset the cumulative or peak power
399                     consumption data (viewed via get-power-consumption-data).
400                     Command  confirmed  to work on Dell Poweredge R610, R710,
401                     R905, M610, M610x, and M910.
402
403              power-supply-info
404                     This OEM command can read and output power supply ratings
405                     and  other  information. This OEM command requires access
406                     to the SDR. Command confirmed to work on  Dell  Poweredge
407                     R610, R710, and M610.
408
409              get-instantaneous-power-consumption-data power_supply_instance
410                     This OEM command can read instantaneous power consumption
411                     data. If a power supply  instance  number  is  specified,
412                     only  data for that instance will be gathered. Otherwise,
413                     collective power consumption will  be  gathered.  Command
414                     confirmed  to  work  on  Dell Poweredge R610, R710, M610,
415                     M610x, and M910.
416
417              get-power-head-room
418                     This OEM command can read power head room.  Command  con‐
419                     firmed  to work on Dell Poweredge R610 and R710 (Dell 11G
420                     Poweredge systems).
421
422              get-power-consumption-statistics average|max|min
423                     This OEM command can read average, max, or min power con‐
424                     sumption  history. Command confirmed to work on Dell Pow‐
425                     eredge R610, R710, M610, M610x, and M910.
426
427              get-power-capacity
428                     This OEM command can read  the  current  power  capacity.
429                     Command  confirmed  to work on Dell Poweredge R610, R710,
430                     M610, M610x, and M910.
431
432              set-power-capacity power-capacity
433                     This OEM command can write  the  current  power  capacity
434                     (specified  in  Watts). Command confirmed to work on Dell
435                     Poweredge R610 and R710 (Dell 11G Poweredge systems).
436
437              get-power-capacity-status
438                     This OEM command  can  determine  if  the  current  power
439                     capacity  is  enabled  or  disabled. Command confirmed to
440                     work on Dell Poweredge R610, R710, M610, M610x, and M910.
441
442              set-power-capacity-status enable|disable
443                     This OEM command can configure the current power capacity
444                     to  be  enabled or disabled. Command confirmed to work on
445                     Dell Poweredge R610 and R710  (Dell  11G  Poweredge  sys‐
446                     tems).
447
448              get-chassis-identify-status
449                     This  OEM command will retrieve the current chassis iden‐
450                     tify (i.e. LED) status. Command confirmed to work on Dell
451                     Poweredge  2900,  2950,  R610,  R710,  R905,  M600, M610,
452                     M610x, and M910.
453
454              slot-power-toggle slot-number
455                     This OEM command will perform a power toggle  on  a  PCIe
456                     slot.  The  PCIe slot number can range from 1 to 16. Com‐
457                     mand confirmed to work on Dell Poweredge C410x.
458
459              slot-power-control platform-model on|off|status slot-number
460                     This OEM command will perform a power control action on a
461                     PCIe  slot.  This OEM extension is tied very closely to a
462                     platform, so a supported platform must be specified.  The
463                     currently supported platform-model options are C410x. The
464                     on action powers on a slot, off powers off  a  slot,  and
465                     status  returns if the current power is on or off. If the
466                     current power status is on, an on  action  does  nothing.
467                     Similarly,  if  the  current  power status is off, an off
468                     action does nothing. The on, off, and status  slot  power
469                     actions  are not native and are emulated through a combi‐
470                     nation of a power toggle (using slot-power-toggle  above)
471                     and  the reading of PCIe slot watt sensors. The PCIe slot
472                     number can range from 1 to 16. Command confirmed to  work
473                     on Dell Poweredge C410x.
474
475              get-port-map
476                     This  OEM command will retrieve the current iPASS mapping
477                     to PCIe controllers/slots. Command confirmed to  work  on
478                     Dell Poweredge C410x.
479
480              set-port-map jumper|bmc ipass-mapping 1:2|1:4|1:8
481                     This  OEM  command will set an iPass mapping to PCIe con‐
482                     trollers/slots.  jumper or bmc must be specified to indi‐
483                     cate  if iPass mappings will be controlled via jumpers on
484                     the system or via a BMC/IPMI. In order  for  reconfigura‐
485                     tion  to  be done via ipmi-oem, the user must select bmc.
486                     The ipass-mapping determines which iPass  ports  will  be
487                     mapped.   1:2,  1:4,  and  1:8 determine the mapping that
488                     should be set. See details below for specific  platforms.
489                     Command  confirmed  to work on Dell Poweredge C410x.  For
490                     the Dell Poweredge C410x, the ipass-mapping ranges from 1
491                     to 4. 1 refers to iPass 1 and 5, 2 to 2 and 6, 3 to 3 and
492                     7, and 4 to 4 and 8. For the platform C410x,  PCIe  slots
493                     1,  2,  3, 4, 13, 14, 15, and 16 are attached to iPass 1,
494                     2, 3, and 4. PCIe slots 5, 6, 7, 8, 9, 10, 11, and 12 are
495                     attached  to iPass 5, 6, 7, and 8. For example, if 1:2 is
496                     set on mapping-number 1, PCIe slots  1  and  15  will  be
497                     assigned  to  iPass 1 and slots 2 and 16 will be assigned
498                     to iPass 5. if 1:4 is chosen, PCIe slots 1, 2, 15, and 16
499                     will be assigned to iPass 1 and iPass 5 will not be used.
500
501       Fujitsu
502
503              get-power-on-source
504                     This  OEM  command  will  return  the reason for the most
505                     recent Power On.  Command confirmed to  work  on  Fujitsu
506                     RX100 S5.
507
508              get-power-off-source
509                     This  OEM  command  will  return  the reason for the most
510                     recent Power Off.  Command confirmed to work  on  Fujitsu
511                     RX100 S5.
512
513              get-remote-storage-status connection_number
514                     This OEM command will return the connection and/or status
515                     of remote storage. connection_number currently supports a
516                     range of 0-1.  Command confirmed to work on Fujitsu RX100
517                     S5.
518
519              get-system-status
520                     This OEM command will return the current  system  status.
521                     Command confirmed to work on Fujitsu RX100 S5.
522
523              get-eeprom-version-info eeprom_number
524                     This OEM command will return the current version info for
525                     various hardware elements, including firmware,  SDR,  and
526                     boot  revision.  eeprom_number currently supports a range
527                     of 0-1. Command confirmed to work on Fujitsu RX100 S5.
528
529              get-identify-led
530                     This OEM command will get the current identify  LED  sta‐
531                     tus. Command confirmed to work on Fujitsu RX100 S5.
532
533              set-identify-led on|off
534                     This  OEM  command will set the current identify LED sta‐
535                     tus. Command confirmed to work on Fujitsu RX100 S5.
536
537              get-error-led
538                     This OEM command will get the current error  LED  status.
539                     Command confirmed to work on Fujitsu RX100 S5.
540
541              get-sel-entry-long-text sel_record_id
542                     This  OEM  command  will  retrieve  the  Fujitsu specific
543                     string interpretation of a SEL record. This  command  may
544                     be useful for interpreting Fujitsu OEM hex codes found in
545                     the SEL. A specific SEL  record  ID  must  be  specified.
546                     Please  see ipmi-sel(8), for retrieving SEL records. Com‐
547                     mand confirmed to work on Fujitsu RX100 S5.
548
549       IBM
550
551              get-led
552                     This OEM command will get the current  LED  status.  This
553                     OEM command requires access to the SDR. Command confirmed
554                     to work on IBM x3755.
555
556       Intel
557
558              get-smtp-config [channel-number]
559                     This OEM command will get the current SMTP  configuration
560                     on the IPMI card. By default, configuration for every LAN
561                     channel will be output.  If a  channel-number  is  speci‐
562                     fied,  only  that specific channel number's configuration
563                     will be output.   Command  confirmed  to  work  on  Intel
564                     S5500WB  (Penguin Computing Relion 700) and Intel S2600JF
565                     (Appro 512X).
566
567              set-smtp-config [channel-number] KEY=VALUE ...
568                     This OEM command will set the current SMTP  configuration
569                     on  the IPMI card. By default, configuration will be done
570                     for all LAN channels.  If a channel-number is  specified,
571                     only that specific channel number's configuration will be
572                     configured.    The   possible   keys   and   values   are
573                     smtp=enable|disable,   smtpserveraddress=ipaddress,  smt‐
574                     pusername=string,      userpassword=string,      emailad‐
575                     dress=string,    subject=string,   messagecontent=string,
576                     senderemailaddress=string, and smtphostname=string.  Mul‐
577                     tiple  key=value  pairs may be specified. If no key=value
578                     pairs are specifed, available pairs are  output.  Command
579                     confirmed  to  work  on  Intel S5500WB (Penguin Computing
580                     Relion 700) and Intel S2600JF (Appro 512X).
581
582              get-power-restore-delay
583                     This OEM command will retrieve the power  on  delay.  The
584                     power  on  delay  is a delay that occurs whenever the BMC
585                     turns on the system according to the Power Restore Policy
586                     setting.  It  does  not take effect otherwise (i.e. power
587                     button or Chassis Control). Command confirmed to work  on
588                     Intel S2600JF (Appro 512X).
589
590              set-power-restore-delay seconds
591                     This  OEM  command  will  set  the  power  on delay. (See
592                     get-power-restore-delay above for  description  on  power
593                     restore  delay).  Command  confirmed  to  work  on  Intel
594                     S2600JF (Appro 512X).
595
596              restore-configuration
597                     This OEM command will restore  BMC  configuration  values
598                     back  to  default values. The command will spin until the
599                     restore is confirmed to be complete.  Command  configured
600                     to  work  on Intel S5500WB (Penguin Computing Relion 700)
601                     and Intel S2600JF (Appro 512X). After running  this  com‐
602                     mand,  the  BMC must be reset to return it to functioning
603                     status. This may be accomplished  by  executing  a  cold-
604                     reset with bmc-device(8).
605
606       IntelNM (Intel Node Manager)
607
608       The  following OEM commands operate on Intel chipsets with Node Manager
609       support. They all require access to the SDR. They may work on  multiple
610       vendors motherboards.
611
612              get-node-manager-statistics [domainid=num] [policyid=num]
613                     This  OEM command will output the Intel Node Manager sta‐
614                     tistics. The user may optionally specify  a  domainid  or
615                     policyid.  The  default  domainid  is 0. If a policyid is
616                     specified, per policy statistics will be  output,  other‐
617                     wise  global statistics will be output. Command confirmed
618                     to work on Intel S5500WB (Penguin Computing Relion  700),
619                     Inventec  5441/5442  (Dell  Xanadu  II/III),  Quanta S99Q
620                     (Dell FS12-TY), Quanta QSSC-S4R (Appro GB812X-CN), Super‐
621                     micro X9DRi-F, Intel S2600JF (Appro 512X).
622
623              reset-node-manager-statistics [domainid=num] [policyid=num]
624                     This  OEM  command will reset the Intel Node Manager sta‐
625                     tistics. The user may optionally specify  a  domainid  or
626                     policyid.  The  default  domainid  is 0. If a policyid is
627                     specified, per policy statistics will be reset, otherwise
628                     global  statistics  will  be  reset. Command confirmed to
629                     work on Intel S5500WB  (Penguin  Computing  Relion  700),
630                     Inventec  5441/5442  (Dell  Xanadu  II/III),  Quanta S99Q
631                     (Dell FS12-TY), Quanta QSSC-S4R (Appro GB812X-CN), Super‐
632                     micro X9DRi-F, Intel S2600JF (Appro 512X).
633
634              get-node-manager-capabilities     [domainid=num]    [policytrig‐
635              ger=none|inlet] [policytype=powercontrol]
636                     This OEM command will output the current capabilities  of
637                     the Intel Node manager. The user may optionally specify a
638                     domainid,  policytrigger,  or  policytype.  The   default
639                     domainid is 0. If any particular option is not specified,
640                     all permutations of the remaining options will be used in
641                     an attempt to output all capabilities of the system. Com‐
642                     mand confirmed to work on Intel S2600JF (Appro 512X).
643
644              node-manager-policy-control   <enable|disable>    [domainid=num]
645              [policyid=num]
646                     This  OEM  command  will  enable  or  disable the current
647                     global, domain, or policies used by the Intel  Node  Man‐
648                     ager.  If no domainid is specified, then the Node Manager
649                     will be enabled or globally disabled.  If a  domainid  is
650                     specified,  only that domain will be enabled or disabled.
651                     If both a domainid and policyid are specified, only  that
652                     specific policy within the domain will be specified. This
653                     OEM command will be required to enable or  disable  poli‐
654                     cies  before  many  of the commands below can be used for
655                     configuration or use. Command confirmed to work on  Intel
656                     S2600JF (Appro 512X).
657
658              get-node-manager-policy [domainid=num] [policyid=num]
659                     This  OEM  command will get the current node manager pol‐
660                     icy. If no domainid is specified, all  policies  for  all
661                     domain IDs and policy Ids will be attempted to be output.
662                     If a domainid is specified but a  policyid  is  not,  all
663                     policies  within a domain will be attempted to be output.
664                     If the verbose option is set, additional  error  messages
665                     will  be output as valid policies are being searched for.
666                     Command confirmed to work on Intel S2600JF (Appro 512X).
667
668              set-node-manager-policy  domainid=num  policyid=num  policytrig‐
669              ger=none|inlet   powerlimit=watts  correctiontimelimit=ms  poli‐
670              cytriggerlimit=num  statisticsreportingperiod=seconds  [policys‐
671              tate=enable|disable] [policyexceptionaction=alert|shutdown]
672                     This  OEM  command will add or modify an indicated policy
673                     ID from the domain ID.  Most  of  the  fields  above  are
674                     required,  although  they  can be listed in any order. By
675                     default any created/modified policy will be enabled, how‐
676                     ever this can be overridden by policystate.  policyexcep‐
677                     tionaction may be specified multiple times  to  configure
678                     multiple  actions  or  can  be  skipped  to  configure no
679                     actions.  When the policytrigger is configured  as  none,
680                     the  trigger  that  will lead to exception actions is the
681                     value specified by the powerlimit. When the policytrigger
682                     is  inlet, the tigger that will lead to exception actions
683                     is the value specified by policytriggerlimit.  The  units
684                     of  the policytriggerlimit will depend on the policytrig‐
685                     ger selected.  Most  notably,  if  the  policytrigger  is
686                     inlet,  which  refers  to inlet temperature, the units of
687                     policytriggerlimit will be in  Celsius.  When  the  poli‐
688                     cytrigger  is  none,  the  policytriggerlimit  is ignored
689                     internally by the Intel Node Manager, but  a  value  must
690                     still be specified for configuration. Typically configur‐
691                     ing it to 0 is more than sufficient. The  correctiontime‐
692                     limit  specifies the time the Node Manager must take cor‐
693                     rective actions to bring back the  system  within  limits
694                     before taking the actions specified in policyexceptionac‐
695                     tion. statisticsreportingperiod is the number of  seconds
696                     that  measured  power  will  be  averaged  for reporting.
697                     Please see get-node-manager-policy  to  determine  proper
698                     ranges  for  powerlimit, correctiontimelimit, policytrig‐
699                     gerlimit, and  statisticsreportingperiod.   Command  con‐
700                     firmed to work on Intel S2600JF (Appro 512X).
701
702              remove-node-manager-policy domainid=num policyid=num
703                     This OEM command will remove the indicated policy ID from
704                     the  domain  ID.  Both  the  domainid  and  policyid  are
705                     required.  Command  confirmed  to  work  on Intel S2600JF
706                     (Appro 512X).
707
708              get-node-manager-alert-thresholds [domainid=num] [policyid=num]
709                     This OEM command will get the current  alert  thresholds.
710                     If  no  domainid  is  specified, all alert thresholds for
711                     domain IDs and policy Ids will be attempted to be output.
712                     If  a  domainid  is  specified but a policyid is not, all
713                     alert thresholds within a domain will be attempted to  be
714                     output.  The  units  of the thresholds will depend on the
715                     configuration of  the  current  policy.  If  the  verbose
716                     option  is  set, additional error messages will be output
717                     as valid policies are being searched  for.  Command  con‐
718                     firmed to work on Intel S2600JF (Appro 512X).
719
720              set-node-manager-alert-thresholds    domainid=num   policyid=num
721              [threshold1=num] [threshold2=num] [threshold3=num]
722                     This OEM command will set  the  alert  thresholds  for  a
723                     given domain ID and policy ID. Up to three thresholds can
724                     be specified, The units of the thresholds will depend  on
725                     the  configuration  of  the  current policy. Command con‐
726                     firmed to work on Intel S2600JF (Appro 512X).
727
728              get-node-manager-policy-suspend-periods  [domainid=num]   [poli‐
729              cyid=num]
730                     This  OEM  command  will  get  the current policy suspend
731                     periods. Suspend periods will temporarily  disable  Intel
732                     Node Manager policies at configured times. If no domainid
733                     is specified, all suspend periods for domain IDs and pol‐
734                     icy Ids will be attempted to be output.  If a domainid is
735                     specified but a policyid  is  not,  all  suspend  periods
736                     within  a  domain  will be attempted to be output. If the
737                     verbose option is set, additional error messages will  be
738                     output  as valid policies are being searched for. Suspend
739                     start and stop times are output in 24 hour  format.  Com‐
740                     mand confirmed to work on Intel S2600JF (Appro 512X).
741
742              set-node-manager-policy-suspend-periods    domainid=num    poli‐
743              cyid=num suspendperiodstart1=time  suspendperiodstop1=time  sus‐
744              pendperiodrepeat1=monday|tuesday|wednesday|thursday|friday|sat‐
745              urday|sunday ...
746                     This OEM command will set the policy suspend periods  for
747                     a policy.  Suspend periods will temporarily disable Intel
748                     Node Manager policies at configured times. Up to  5  sus‐
749                     pend  periods  can  be  specified by suspendperiodstartX,
750                     suspendperiodstopX, suspendperiodrepeatX.  suspendperiod‐
751                     start  and  suspendperiodstop  specify the start and stop
752                     time since midnight for a suspend period. The time should
753                     be  specified  in  24  hour format (i.e. 02:00 or 13:40).
754                     Note that suspend periods are configured in multiples  of
755                     6  minutes,  therefore  the  stored  configuration may be
756                     rounded to a slightly alternate configuration.   suspend‐
757                     periodrepeat  indicates  the  days  in  which the suspend
758                     period shall be enabled. The option can be specified mul‐
759                     tiple  times  to  configure  multiple times. Command con‐
760                     firmed to work on Intel S2600JF (Appro 512X).
761
762              set-node-manager-power-draw-range     domainid=num     minpower‐
763              drawrange=watts maxpowerdrawrange=watts
764                     This  OEM  command  will  set  the power draw range for a
765                     given domain ID.  After this configuration, any  policies
766                     within  the domain ID that are outside of this range will
767                     be disabled as needed. The current power draw  range  can
768                     be read via the get-node-manager-capabilities above. Com‐
769                     mand confirmed to work on Intel S2600JF (Appro 512X).
770
771              get-node-manager-version
772                     This OEM command will output the current Intel Node  Man‐
773                     ager  version  information.  Command confirmed to work on
774                     Intel S5500WB (Penguin Computing  Relion  700),  Inventec
775                     5441/5442   (Dell   Xanadu  II/III),  Quanta  S99Q  (Dell
776                     FS12-TY),  Quanta  QSSC-S4R  (Appro   GB812X-CN),   Intel
777                     S2600JF (Appro 512X).
778
779       Inventec
780
781              get-nic-mode
782                     This  OEM  command will determine the current NIC mode as
783                     dedicated or shared. Dedicated  indicates  IPMI  is  only
784                     available  on the dedicated management port. Shared indi‐
785                     cates IPMI is also available on one of the primary ether‐
786                     net   ports.   Command  confirmed  to  work  on  Inventec
787                     5441/5442 (Dell Xanadu II/III).
788
789              set-nic-mode dedicated|shared
790                     This OEM command will set the current NIC mode  to  dedi‐
791                     cated  or shared. (See get-nic-mode above for description
792                     on dedicated vs.  shared  mode.)  This  OEM  command  may
793                     internally  reset  the  BMC,  making the BMC unusable for
794                     awhile. Command confirmed to work on  Inventec  5441/5442
795                     (Dell Xanadu II/III).
796
797              get-mac-address
798                     This  command  will retrieve the BMC MAC address. This is
799                     actually not an OEM command, but rather the  normal  IPMI
800                     MAC  address  command  (identical  to what is used in the
801                     bmc-config(8) tool). This command is placed here for con‐
802                     venience.
803
804              set-mac-address dedicated|shared MACADDR
805                     This OEM command will set the dedicated or shared BMC MAC
806                     address.  (See get-nic-mode above for description on ded‐
807                     icated  vs.  shared  mode.) The BMC MAC address cannot be
808                     set through the normal IPMI MAC address command (what  is
809                     used  in  the  bmc-config(8) tool). The MACADDR should be
810                     specified in XX:XX:XX:XX:XX:XX form.  A  shared  BMC  MAC
811                     address  may  conflict with normal communication ethernet
812                     communication on the primary  ethernet  port.  Users  may
813                     wish  to  configuration an alternate MAC address instead.
814                     After configuration of the MAC address, the BMC  must  be
815                     reset. This may be accomplished by executing a cold-reset
816                     with bmc-device(8).  Command confirmed to work on  Inven‐
817                     tec 5441/5442 (Dell Xanadu II/III).
818
819              get-bmc-services
820                     This  OEM  command will display the currently enabled BMC
821                     services.   Command  confirmed  to   work   on   Inventec
822                     5441/5442 (Dell Xanadu II/III).
823
824              set-bmc-services enable|disable all|kvm|http|ssh
825                     This  OEM  command  will enable or disable other BMC ser‐
826                     vices besides IPMI. all can be specified  to  enable/dis‐
827                     able all services, kvm specifies KVM and Virtual Storage,
828                     http specifies HTTP and HTTPS, and ssh specifies both SSH
829                     and   Telnet.  Command  confirmed  to  work  on  Inventec
830                     5441/5442 (Dell Xanadu II/III).
831
832              get-authentication-config
833                     This OEM command will display additional OEM  authentica‐
834                     tion  settings.  (See set-authentication-config below for
835                     description on outputs.) Command  confirmed  to  work  on
836                     Inventec 5441/5442 (Dell Xanadu II/III).
837
838              set-authentication-config KEY=VALUE ...
839                     This  OEM  command will set additional OEM authentication
840                     settings on the IPMI card. The possible keys  and  values
841                     are  maxauthenticationfailures=count,  lockoutwindow=sec‐
842                     onds, lockouttime=seconds, and httpsportnumber=num.  max‐
843                     authenticationfailures  specifies  the  maximum number of
844                     allowed authentication failures. lockoutwindow  specifies
845                     the  window  of time the authentication failure count can
846                     be reached in to disable a  user.  lockouttime  specifies
847                     the  time period a user is disabled if the authentication
848                     failure count is reached. Setting 0 to any  of  the  set‐
849                     tings  will disable the lockout feature. Each time any of
850                     these settings is modified,  the  authentication  failure
851                     count  of  each  enabled  user  is  reset  to 0. Multiple
852                     key=value pairs may be specified. If no  key=value  pairs
853                     are  specifed,  available  pairs are output. Command con‐
854                     firmed  to  work  on  Inventec  5441/5442  (Dell   Xanadu
855                     II/III).
856
857              get-account-status
858                     This  OEM  command will output the current account status
859                     of users on the BMC. This command is particularly  usefor
860                     for determinining which users in the system may have been
861                     locked out via  authentication  failures  configured  via
862                     set-authentication-config.  Command  confirmed to work on
863                     Inventec 5441/5442 (Dell Xanadu II/III).
864
865              get-dns-config
866                     This OEM command will display  additional  OEM  DNS  set‐
867                     tings.  (See set-dns-config below for description on out‐
868                     puts.) Command confirmed to work  on  Inventec  5441/5442
869                     (Dell Xanadu II/III).
870
871              set-dns-config KEY=VALUE ...
872                     This  OEM command will set additional OEM DNS settings on
873                     the IPMI card. The possible keys  and  values  are  dnsd‐
874                     hcp=enable|disable,                 dnsserver1=ipaddress,
875                     dnsserver2=ipaddress, dnsregisterbmc=enable|disable, dns‐
876                     bmchostname=string, dnsdomainnamedhcp=enable|disable, and
877                     dnsdomainname=string. dnsdhcp specifies if the DNS server
878                     IP  addresses  should  be  assigned from the DHCP server.
879                     dnsserver1 and  dnsserver2  specify  the  IP  addess  for
880                     server  1  and 2 respectively. These fields are read only
881                     if dnsdhcp and DHCP are enabled. dnsregisterbmc specifies
882                     if  the  BMC  host name is registered via the DNS server.
883                     dnsbmchostname specifies the BMC host name. This field is
884                     read only if dnsregisterbmc is enabled. dnsdomainnamedhcp
885                     specifies if the DNS domainname should be  assigned  from
886                     the  DHCP  server. dnsdomainname specifies the DNS domain
887                     name string. This field is read only if dnsdomainnamedhcp
888                     is enabled. Multiple key=value pairs may be specified. If
889                     no key=value pairs are specifed, available pairs are out‐
890                     put.  Command  confirmed  to  work  on Inventec 5441/5442
891                     (Dell Xanadu II/III).
892
893              get-web-server-config
894                     This OEM command will get the current web server configu‐
895                     ration  on  the  IPMI  card. Command confirmed to work on
896                     Inventec 5441/5442 (Dell Xanadu II/III).
897
898              set-web-server-config KEY=VALUE ...
899                     This OEM command will set the current web server configu‐
900                     ration on the IPMI card. The possible keys and values are
901                     webserver=enable|disable, webservertimeout=seconds, http‐
902                     portnumber=num,    and    httpsportnumber=num.   Multiple
903                     key=value pairs may be specified. If no  key=value  pairs
904                     are  specifed,  available  pairs are output. Command con‐
905                     firmed  to  work  on  Inventec  5441/5442  (Dell   Xanadu
906                     II/III).
907
908              get-power-management-config
909                     This  OEM  command  will get the current power management
910                     configuration on the IPMI card. Command confirmed to work
911                     on Inventec 5441/5442 (Dell Xanadu II/III).
912
913              set-power-management-config KEY=VALUE ...
914                     This  OEM  command  will set the current power management
915                     configuration on the IPMI card.  The  possible  keys  and
916                     values are dpnmpowermanagement=enable|disable, powerstag‐
917                     geringacrecovery=immediate|auto|user,   powerondelay=sec‐
918                     onds,  and  maxpowerondelay=seconds.  dpnmpowermanagement
919                     enables or diables DPNM, Dynamic Power  Node  Management.
920                     For  powerstaggeringacrecovery,  immediate  specifies  no
921                     delay, auto generates a delay time  between  the  minimum
922                     and  maximum  configured,  and user uses the user defined
923                     time defined by powerondelay. powerondelay must be within
924                     the  minimum  and  maximum power on delay times. Multiple
925                     key=value pairs may be specified. If no  key=value  pairs
926                     are  specifed,  available  pairs are output. Command con‐
927                     firmed  to  work  on  Inventec  5441/5442  (Dell   Xanadu
928                     II/III).
929
930              get-sol-idle-timeout
931                     This  OEM  command will get the SOL idle timeout. Command
932                     confirmed to work  on  Inventec  5441/5442  (Dell  Xanadu
933                     II/III).
934
935              set-sol-idle-timeout idle-timeout
936                     This  OEM  command  will  set  the  SOL idle timeout. The
937                     idle-timeout is one-based, max  of  65535,  in  1  minute
938                     increments  (e.g. 1 = 1 minute), 0 or "none" will config‐
939                     ure no timeout. Command confirmed  to  work  on  Inventec
940                     5441/5442 (Dell Xanadu II/III).
941
942              get-telnet-ssh-redirect-status
943                     This OEM command will get the telnet/SSH redirect status.
944                     Command confirmed to work on Inventec 5442  (Dell  Xanadu
945                     III).
946
947              set-telnet-ssh-redirect-status enable|disable
948                     This  OEM command will enable or disable telnet/SSH redi‐
949                     rect status.  Command confirmed to work on Inventec  5442
950                     (Dell Xanadu III).
951
952              get-board-id
953                     This  OEM command can get the board ID. Command confirmed
954                     to work on Inventec 5441/5442 (Dell Xanadu II/III).
955
956              set-board-id ID
957                     This OEM command can set the board ID. Command  confirmed
958                     to work on Inventec 5441/5442 (Dell Xanadu II/III).
959
960              get-fcb-version
961                     This OEM command can get the fan control board (FCB) ver‐
962                     sion number.   Command  confirmed  to  work  on  Inventec
963                     5441/5442 (Dell Xanadu II/III).
964
965              set-fcb-version majorversion minorversion
966                     This OEM command can set the fan control board (FCB) ver‐
967                     sion number.  The majorversion and minorversion  must  be
968                     specified  in  hex. Command confirmed to work on Inventec
969                     5441/5442 (Dell Xanadu II/III).
970
971              get-sol-inactivity-timeout
972                     This OEM command will retrieve the SOL  inactivity  time‐
973                     out.  Command  confirmed  to  work  on Inventec 5441/5442
974                     (Dell Xanadu II/III).
975
976              set-sol-inactivity-timeout inactivity-timeout
977                     This OEM command will set the SOL inactivity timeout. The
978                     inactivity-timeout  is  one-based,  max  of  65535,  in 1
979                     minute increments (e.g. 1 = 1 minute), 0 or  "none"  will
980                     configure  no  timeout.   Command  confirmed  to  work on
981                     Inventec 5441/5442 (Dell Xanadu II/III).
982
983              restore-to-defaults all|user|lan|sol|serial|pef
984                     This OEM command will restore certain  BMC  configuration
985                     sections  back  to  default values. The command will spin
986                     until the reset is confirmed to be complete. Command con‐
987                     firmed  to work on Inventec 5442 (Dell Xanadu III). After
988                     running this command, the BMC must be reset to return  it
989                     to  functioning  status. This may be accomplished by exe‐
990                     cuting a cold-reset with bmc-device(8).
991
992              read-eeprom at24c256n
993                     This OEM command will read the specified eeprom.  Command
994                     confirmed  to  work on Inventec 5441 (Dell Xanadu II) for
995                     at24c256.
996
997              clear-eeprom at24c256n
998                     This OEM command will clear the specified  eeprom,  over‐
999                     writing  all  bytes  with  0xFF. If the verbose option is
1000                     set, progress percent will be output as the  clearing  is
1001                     being  done.  Command  confirmed to work on Inventec 5441
1002                     (Dell Xanadu II) for at24c256.
1003
1004       Quanta
1005
1006              get-nic-mode
1007                     This OEM command will determine the current NIC  mode  as
1008                     dedicated  or  shared.  Dedicated  indicates IPMI is only
1009                     available on the dedicated management port. Shared  indi‐
1010                     cates IPMI is also available on one of the primary ether‐
1011                     net ports. Command confirmed to work on Quanta S99Q (Dell
1012                     FS12-TY).
1013
1014              set-nic-mode dedicated|shared
1015                     This  OEM  command will set the current NIC mode to dedi‐
1016                     cated or shared.  (See get-nic-mode above for description
1017                     on  dedicated  vs.  shared  mode.)  This  OEM command may
1018                     internally reset the BMC, making  the  BMC  unusable  for
1019                     awhile.  Command  confirmed  to work on Quanta S99Q (Dell
1020                     FS12-TY).
1021
1022              get-bmc-services
1023                     This OEM command will display the currently  enabled  BMC
1024                     services.  Command confirmed to work on Quanta S99Q (Dell
1025                     FS12-TY).
1026
1027              set-bmc-services enable|disable all|kvm|http|ssh
1028                     This OEM command will enable or disable  other  BMC  ser‐
1029                     vices  besides  IPMI. all can be specified to enable/dis‐
1030                     able all services, kvm specifies KVM and Virtual Storage,
1031                     http specifies HTTP and HTTPS, and ssh specifies both SSH
1032                     and Telnet. Command confirmed  to  work  on  Quanta  S99Q
1033                     (Dell FS12-TY).
1034
1035              get-account-status
1036                     This  OEM  command will output the current account status
1037                     of users on the BMC. This command is particularly  usefor
1038                     for determinining which users in the system may have been
1039                     locked out via authentication failures. Command confirmed
1040                     to work on Quanta S99Q (Dell FS12-TY).
1041
1042              get-dns-config
1043                     This  OEM  command  will  display additional OEM DNS set‐
1044                     tings.  (See set-dns-config below for description on out‐
1045                     puts.)  Command  confirmed  to  work on Quanta S99Q (Dell
1046                     FS12-TY).
1047
1048              set-dns-config KEY=VALUE ...
1049                     This OEM command will set additional OEM DNS settings  on
1050                     the  IPMI  card.  The  possible keys and values are dnsd‐
1051                     hcp=enable|disable,                 dnsserver1=ipaddress,
1052                     dnsserver2=ipaddress, dnsregisterbmc=enable|disable, dns‐
1053                     bmchostname=string, dnsdomainnamedhcp=enable|disable, and
1054                     dnsdomainname=string. dnsdhcp specifies if the DNS server
1055                     IP addresses should be assigned  from  the  DHCP  server.
1056                     dnsserver1  and  dnsserver2  specify  the  IP  addess for
1057                     server 1 and 2 respectively. These fields are  read  only
1058                     if dnsdhcp and DHCP are enabled. dnsregisterbmc specifies
1059                     if the BMC host name is registered via  the  DNS  server.
1060                     dnsbmchostname specifies the BMC host name. This field is
1061                     read only if dnsregisterbmc is enabled. dnsdomainnamedhcp
1062                     specifies  if  the DNS domainname should be assigned from
1063                     the DHCP server. dnsdomainname specifies the  DNS  domain
1064                     name string. This field is read only if dnsdomainnamedhcp
1065                     is enabled. Multiple key=value pairs may be specified. If
1066                     no key=value pairs are specifed, available pairs are out‐
1067                     put. Command confirmed  to  work  on  Quanta  S99Q  (Dell
1068                     FS12-TY).
1069
1070              get-web-server-config
1071                     This OEM command will get the current web server configu‐
1072                     ration on the IPMI card. Command  confirmed  to  work  on
1073                     Quanta S99Q (Dell FS12-TY).
1074
1075              set-web-server-config KEY=VALUE ...
1076                     This OEM command will set the current web server configu‐
1077                     ration on the IPMI card. The possible keys and values are
1078                     webserver=enable|disable, webservertimeout=seconds, http‐
1079                     portnumber=num,   and    httpsportnumber=num.    Multiple
1080                     key=value  pairs  may be specified. If no key=value pairs
1081                     are specifed, available pairs are  output.  Command  con‐
1082                     firmed to work on Quanta S99Q (Dell FS12-TY).
1083
1084              get-power-management-config
1085                     This  OEM  command  will get the current power management
1086                     configuration on the IPMI card. Command confirmed to work
1087                     on Quanta S99Q (Dell FS12-TY).
1088
1089              set-power-management-config KEY=VALUE ...
1090                     This  OEM  command  will set the current power management
1091                     configuration on the IPMI card.  The  possible  keys  and
1092                     values are dpnmpowermanagement=enable|disable, powerstag‐
1093                     geringacrecovery=immediate|auto|user,   powerondelay=sec‐
1094                     onds,  and  maxpowerondelay=seconds.  dpnmpowermanagement
1095                     enables or diables DPNM, Dynamic Power  Node  Management.
1096                     For  powerstaggeringacrecovery,  immediate  specifies  no
1097                     delay, auto generates a delay time  between  the  minimum
1098                     and  maximum  configured,  and user uses the user defined
1099                     time defined by powerondelay. powerondelay must be within
1100                     the  minimum  and  maximum power on delay times. Multiple
1101                     key=value pairs may be specified. If no  key=value  pairs
1102                     are  specifed,  available  pairs are output. Command con‐
1103                     firmed to work on Quanta S99Q (Dell FS12-TY).
1104
1105              get-sol-idle-timeout
1106                     This OEM command will get the SOL idle  timeout.  Command
1107                     confirmed to work on Quanta S99Q (Dell FS12-TY).
1108
1109              set-sol-idle-timeout idle-timeout
1110                     This  OEM  command  will  set  the  SOL idle timeout. The
1111                     idle-timeout is one-based, max  of  65535,  in  1  minute
1112                     increments  (e.g. 1 = 1 minute), 0 or "none" will config‐
1113                     ure no timeout. Command confirmed to work on Quanta  S99Q
1114                     (Dell FS12-TY).
1115
1116              get-telnet-ssh-redirect-status
1117                     This OEM command will get the telnet/SSH redirect status.
1118                     Command confirmed to work on Quanta S99Q (Dell FS12-TY).
1119
1120              set-telnet-ssh-redirect-status enable|disable
1121                     This OEM command will enable or disable telnet/SSH  redi‐
1122                     rect  status.   Command  confirmed to work on Quanta S99Q
1123                     (Dell FS12-TY).
1124
1125              reset-to-defaults all|user|lan|sol|serial|pef
1126                     This OEM command will  reset  certain  BMC  configuration
1127                     sections  back  to  default values. The command will spin
1128                     until the reset is confirmed to be complete. Command con‐
1129                     firmed to work on Quanta S99Q (Dell FS12-TY).  After run‐
1130                     ning this command, the BMC must be reset to return it  to
1131                     functioning status. This may be accomplished by executing
1132                     a cold-reset with bmc-device(8).
1133
1134              get-processor-information [processor-index]
1135                     This OEM command will determine system processor informa‐
1136                     tion.  By  default, information about each processor will
1137                     be output. If a processor-index is specified,  only  that
1138                     specific  processor  will be output. Command confirmed to
1139                     work on Quanta S99Q (Dell FS12-TY).
1140
1141              read-mac-address s99q dedicated|shared
1142                     This command will read the currently configured dedicated
1143                     or  shared  MAC  address  for a specified motherboard. It
1144                     will read the MAC address directly from the  BMC  eeprom.
1145                     Command  confirmed  to work on Quanta S99Q (Dell FS12-TY)
1146                     for s99q.
1147
1148              write-mac-address s99q dedicated|shared MACADDR
1149                     This OEM command will set the dedicated or shared BMC MAC
1150                     address  for  a specified motherboard. It will be written
1151                     directly to the BMC eeprom. (See get-nic-mode  above  for
1152                     description  on  dedicated  vs. shared mode.) The BMC MAC
1153                     address cannot be set through the normal IPMI MAC address
1154                     command  (what  is  used  in the bmc-config(8) tool). The
1155                     MACADDR should be specified in XX:XX:XX:XX:XX:XX form.  A
1156                     shared  BMC MAC address may conflict with normal communi‐
1157                     cation ethernet communication  on  the  primary  ethernet
1158                     port.  Users  may  wish to configuration an alternate MAC
1159                     address instead. After configuration of the MAC  address,
1160                     the  BMC  must be reset. This may be accomplished by exe‐
1161                     cuting a cold-reset  with  bmc-device(8).   Command  con‐
1162                     firmed to work on Quanta S99Q (Dell FS12-TY) for s99q.
1163
1164       Sun
1165
1166              get-led
1167                     This  OEM command will output current LED mode. off indi‐
1168                     cates the LED is steady off,  on  indicates  the  LED  is
1169                     steady  on,  standby  indicates the LED blinks at a 100ms
1170                     on, 2900ms off rate, slow indicates the LED  is  blinking
1171                     at  1Hz,  and  fast indicates the LED is blinking at 4Hz.
1172                     If the verbose option is set, sensor names will be output
1173                     with their entity ID and instance when appropriate. (Sim‐
1174                     ilar to the  --entity-sensor-names  option  in  ipmi-sen‐
1175                     sors.)  This OEM command requires access to the SDR. Com‐
1176                     mand confirmed to work on Sun Fire 4140 with ILOM.
1177
1178              set-led record_id off|on|standby|slow|fast
1179                     This OEM command will configure LED modes.  (See  get-led
1180                     above  for  description  on  LED modes.) This OEM command
1181                     requires access to the SDR. Command confirmed to work  on
1182                     Sun Fire 4140 with ILOM.
1183
1184       Supermicro
1185
1186              extra-firmware-info
1187                     This  OEM command will output additional firmware version
1188                     information.  Command confirmed  to  work  on  Supermicro
1189                     H8QME.
1190
1191              reset-intrusion
1192                     This  OEM  command  will  reset the motherboard intrusion
1193                     flag after it has been triggered. For example,  in  ipmi-
1194                     sensors  or  ipmi-sel,  you may notice a 'General Chassis
1195                     Intrusion' if the motherboard chassis is  not  open,  but
1196                     was  opened  in  the  past.  Command confirmed to work on
1197                     Supermicro H8QME.
1198
1199              get-bmc-services-status
1200                     This OEM command  will  determine  if  non-IPMI  services
1201                     (e.g.  ssh, http, https, vnc, etc.) are currently enabled
1202                     or disabled on the BMC.  Command  confirmed  to  work  on
1203                     Supermicro X8DTG.
1204
1205              set-bmc-services-status enable|disable
1206                     This OEM command will enable or disable all non-IPMI ser‐
1207                     vices on the BMC. This command can be used to  enable  or
1208                     disable  non-IPMI  services such as ssh, http, https, and
1209                     vnc. Command confirmed to work on Supermicro X8DTG.
1210
1211       Wistron
1212
1213              get-system-info KEY
1214                     This OEM command  can  retrieve  the  motherboard  system
1215                     information.   Valid  keys  are  asset-tag,  service-tag,
1216                     product-name. Command confirmed to work on Wistron / Dell
1217                     Poweredge C6220.
1218
1219              get-nic-mode
1220                     This  OEM  command will determine the current NIC mode as
1221                     dedicated or shared. Dedicated  indicates  IPMI  is  only
1222                     available  on the dedicated management port. Shared indi‐
1223                     cates IPMI is also available on one of the primary ether‐
1224                     net  ports.  Command  confirmed to work on Wistron / Dell
1225                     Poweredge C6220.
1226
1227              set-nic-mode dedicated|shared
1228                     This OEM command will set the current NIC mode  to  dedi‐
1229                     cated or shared.  (See get-nic-mode above for description
1230                     on dedicated vs. shared mode.) After  running  this  com‐
1231                     mand,  the  BMC may need to be reset to finalize the con‐
1232                     figuration. This may be accomplished by executing a cold-
1233                     reset  with  bmc-device(8).  Command confirmed to work on
1234                     Wistron / Dell Poweredge C6220.
1235
1236              get-shared-nic-selection
1237                     This OEM command will determine the current NIC  IPMI  is
1238                     shared  with  if  the  mode  is shared. (See get-nic-mode
1239                     above for description on dedicated vs. shared mode.) Com‐
1240                     mand confirmed to work on Wistron / Dell Poweredge C6220.
1241
1242              set-shared-nic-selection nic1|nic2|nic3|nic4|clear
1243                     This  OEM command will set the current NIC sharing selec‐
1244                     tion. If the current NIC mode is dedicated it  is  advis‐
1245                     able to clear this setting with the clear option. Command
1246                     confirmed to work on Wistron / Dell Poweredge C6220.
1247
1248              get-bmc-services
1249                     This OEM command will display the currently  enabled  BMC
1250                     services.   Command  confirmed  to work on Wistron / Dell
1251                     Poweredge C6220.
1252
1253              set-bmc-services enable|disable all|kvm|http|ssh|snmp|telnet
1254                     This OEM command will enable or disable  other  BMC  ser‐
1255                     vices  besides  IPMI. all can be specified to enable/dis‐
1256                     able all services, kvm specifies KVM and Virtual Storage,
1257                     http  specifies HTTP and HTTPS. Command confirmed to work
1258                     on Wistron / Dell Poweredge C6220.
1259
1260              get-account-status
1261                     This OEM command will output the current  account  status
1262                     of  users on the BMC. This command is particularly usefor
1263                     for determinining which users in the system may have been
1264                     locked out via authentication failures. Command confirmed
1265                     to work on Wistron / Dell Poweredge C6220.
1266
1267              get-dns-config
1268                     This OEM command will display  additional  OEM  DNS  set‐
1269                     tings.  (See set-dns-config below for description on out‐
1270                     puts.) Command confirmed to work on Wistron /  Dell  Pow‐
1271                     eredge C6220.
1272
1273              set-dns-config KEY=VALUE ...
1274                     This  OEM command will set additional OEM DNS settings on
1275                     the IPMI card. The possible keys  and  values  are  dnsd‐
1276                     hcp=enable|disable,                 dnsserver1=ipaddress,
1277                     dnsserver2=ipaddress, dnsregisterbmc=enable|disable, dns‐
1278                     bmchostname=string,     dnsdomainnamedhcp=enable|disable,
1279                     dnsdomainname=string,  and  dnsregistrationdelay=seconds.
1280                     dnsdhcp  specifies  if the DNS server IP addresses should
1281                     be  assigned  from  the  DHCP  server.   dnsserver1   and
1282                     dnsserver2  specify  the  IP  addess  for  server 1 and 2
1283                     respectively. These fields are read only if  dnsdhcp  and
1284                     DHCP  are  enabled.  dnsregisterbmc  specifies if the BMC
1285                     host name is registered via the DNS  server.  dnsbmchost‐
1286                     name specifies the BMC host name. This field is read only
1287                     if dnsregisterbmc is enabled. dnsdomainnamedhcp specifies
1288                     if  the  DNS  domainname should be assigned from the DHCP
1289                     server.  dnsdomainname  specifies  the  DNS  domain  name
1290                     string.  This  field is read only if dnsdomainnamedhcp is
1291                     enabled. dnsregistrationdelay specifies the delay the BMC
1292                     should  take  after  the  IPMI process is up and running.
1293                     Multiple  key=value  pairs  may  be  specified.   If   no
1294                     key=value pairs are specifed, available pairs are output.
1295                     Command confirmed to work on  Wistron  /  Dell  Poweredge
1296                     C6220.
1297
1298              get-web-server-config
1299                     This OEM command will get the current web server configu‐
1300                     ration on the IPMI card. Command  confirmed  to  work  on
1301                     Wistron / Dell Poweredge C6220.
1302
1303              set-web-server-config KEY=VALUE ...
1304                     This OEM command will set the current web server configu‐
1305                     ration on the IPMI card. The possible keys and values are
1306                     webserver=enable|disable, webservertimeout=seconds, http‐
1307                     portnumber=num,   and    httpsportnumber=num.    Multiple
1308                     key=value  pairs  may be specified. If no key=value pairs
1309                     are specifed, available pairs are  output.  Command  con‐
1310                     firmed to work on Wistron / Dell Poweredge C6220.
1311
1312              get-power-management-config
1313                     This  OEM  command  will get the current power management
1314                     configuration on the IPMI card. Command confirmed to work
1315                     on Wistron / Dell Poweredge C6220.
1316
1317              set-power-management-config KEY=VALUE ...
1318                     This  OEM  command  will set the current power management
1319                     configuration on the IPMI card.  The  possible  keys  and
1320                     values are powerstaggeringacrecovery=immediate|auto|user,
1321                     powerondelay=seconds,  and  maxpowerondelay=seconds.  For
1322                     powerstaggeringacrecovery,  immediate specifies no delay,
1323                     auto generates a delay time between the minimum and maxi‐
1324                     mum  configured,  and  user  uses  the  user defined time
1325                     defined by powerondelay. powerondelay must be within  the
1326                     minimum  and  maximum  power  on  delay  times.  Multiple
1327                     key=value pairs may be specified. If no  key=value  pairs
1328                     are  specifed,  available  pairs are output. Command con‐
1329                     firmed to work on Wistron / Dell Poweredge C6220.
1330
1331              get-ipv6-settings
1332                     This OEM command will get the current  IPv6  settings  on
1333                     the  IPMI  card.  Command  confirmed to work on Wistron /
1334                     Dell Poweredge C6220.
1335
1336              set-ipv6-settings KEY=VALUE ...
1337                     This OEM command will set the current  IPv6  settings  on
1338                     the   IPMI  card.   The  possible  keys  and  values  are
1339                     ipv6=enable|disable,   ipv6address=ipaddress,   ipv6gate‐
1340                     wayaddress=ipaddress,  ipv6prefixlength=length, ipv6auto‐
1341                     config=enable|disable,        ipv6autodns=enable|disable,
1342                     ipv6dnsserver1=ipaddress,  and  ipv6dnsserver2=ipaddress.
1343                     If no key=value pairs are specifed, available  pairs  are
1344                     output.  Some  fields  may  be read-only on specific Pow‐
1345                     eredge systems. Command confirmed to work  on  Wistron  /
1346                     Dell Poweredge C6220.
1347
1348              get-ipv6-trap-settings
1349                     This OEM command will get the current IPv6 SNMP trap set‐
1350                     tings on the IPMI card.  Command  confirmed  to  work  on
1351                     Wistron / Dell Poweredge C6220.
1352
1353              set-ipv6-trap-settings index KEY=VALUE ...
1354                     This OEM command will set the current IPv6 SNMP trap set‐
1355                     tings on the IPMI card. The  index  indicates  the  index
1356                     position  for  the configuration. It is followed by a set
1357                     of configuration keys and values. The possible  keys  and
1358                     values  are  destinationtype=pet|oem1|oem2, alertacktime‐
1359                     out=seconds, retries=count, and ipv6snmptrapaddress=ipad‐
1360                     dress.  If  no  key=value  pairs  are specifed, available
1361                     pairs are output. Some fields may be  read-only  on  spe‐
1362                     cific  Poweredge  systems.  Command  confirmed to work on
1363                     Wistron / Dell Poweredge C6220.
1364
1365              get-sol-idle-timeout
1366                     This OEM command will get the SOL idle  timeout.  Command
1367                     confirmed to work on Wistron / Dell Poweredge C6220.
1368
1369              set-sol-idle-timeout idle-timeout
1370                     This  OEM  command  will  set  the  SOL idle timeout. The
1371                     idle-timeout is one-based, max  of  65535,  in  1  minute
1372                     increments  (e.g. 1 = 1 minute), 0 or "none" will config‐
1373                     ure no timeout. Command confirmed to work  on  Wistron  /
1374                     Dell Poweredge C6220.
1375
1376              get-telnet-redirect-function
1377                     This  OEM  command will get the telnet redirect function.
1378                     Command confirmed to work on  Wistron  /  Dell  Poweredge
1379                     C6220.
1380
1381              set-telnet-redirect-function disable|solenable|smashenable
1382                     This  OEM  command will enable or disable telnet redirect
1383                     function.  Command confirmed to work on  Wistron  /  Dell
1384                     Poweredge C6220.
1385
1386              get-dhcp-retry
1387                     This  OEM  command  will retrieve DHCP retry information.
1388                     Wistron / Dell Poweredge C6220.
1389
1390              set-dhcp-retry retry-count retry-interval retry-timeout
1391                     This OEM command will set  DHCP  retry  information.  The
1392                     retry-count  is  one-based,  max of 254, 0 or "none" will
1393                     configure no retries, 255 or "indefinite" will  configure
1394                     constant  retries. The retry-interval is one-based, in 10
1395                     second increments (e.g. 1 = 10 seconds). The  retry-time‐
1396                     out  is  one-based,  in  1  minute increments (e.g. 1 = 1
1397                     minute).  After running this command, the BMC may need to
1398                     be  reset  to  finalize  the  configuration.  This may be
1399                     accomplished  by  executing  a   cold-reset   with   bmc-
1400                     device(8).   Command  confirmed to work on Wistron / Dell
1401                     Poweredge C6220.
1402
1403              get-link-status-change-control
1404                     This OEM command will get the current link status  change
1405                     control.  If  it  reports "Link Down Resilience Enabled",
1406                     BMC firmware will do nothing upon detecting  Link  Status
1407                     Change  until  the  DHCP  lease is expired. If it reports
1408                     "DHCP Re-Discovery Enabled", BMC  firmware  will  perform
1409                     DHCP Discovery upon detecting link status going down than
1410                     back up. Command confirmed to work on Wistron / Dell Pow‐
1411                     eredge C6220..
1412
1413              set-link-status-change-control link_resilience|dhcp_rediscovery
1414                     This  OEM  command  will  set the current NIC link status
1415                     change control setting. (See  set-link-status-change-con‐
1416                     trol  above  for description of arguments). After running
1417                     this command, the BMC may need to be  reset  to  finalize
1418                     the  configuration. This may be accomplished by executing
1419                     a cold-reset with bmc-device(8).   Command  confirmed  to
1420                     work on Wistron / Dell Poweredge C6220.
1421
1422              set-password-policy <enable|disable>
1423                     This  OEM  command  will  set the current password policy
1424                     enforcement. If password policy is enabled, BMC passwords
1425                     must  meet  the  following  requirements: Not contain the
1426                     user's name, be 8-14 characters long, and  contain  three
1427                     of the following four, an English uppercase character (A-
1428                     Z), an English lowercase character (a-z), a digit  (0-9),
1429                     a special character (!, $, #, %, etc.). Command confirmed
1430                     to work on Wistron / Dell Poweredge C6220.
1431
1432              read-proprietary-string
1433                     This OEM command will read the proprietary string  stored
1434                     in  the FRU.  The proprietary string is a string the user
1435                     may set for any management purpose. It can also  be  read
1436                     via  ipmi-fru.   Command  confirmed  to work on Wistron /
1437                     Dell Poweredge C6220.
1438
1439              set-proprietary-string <string>
1440                     This OEM command will write the proprietary string stored
1441                     in  the FRU.  The maximum length string is 80 characters.
1442                     Command confirmed to work on  Wistron  /  Dell  Poweredge
1443                     C6220.
1444
1445              clear-proprietary-string
1446                     This OEM command will clear the proprietary string stored
1447                     in the FRU.  Command confirmed to work on Wistron /  Dell
1448                     Poweredge C6220.
1449

HOSTRANGED SUPPORT

1451       Multiple hosts can be input either as an explicit comma separated lists
1452       of hosts or a range of hostnames in  the  general  form:  prefix[n-m,l-
1453       k,...],  where  n < m and l < k, etc. The later form should not be con‐
1454       fused with regular expression character classes (also denoted  by  []).
1455       For example, foo[19] does not represent foo1 or foo9, but rather repre‐
1456       sents a degenerate range: foo19.
1457
1458       This range syntax is meant only as a convenience  on  clusters  with  a
1459       prefixNN  naming  convention  and specification of ranges should not be
1460       considered necessary -- the list foo1,foo9 could be specified as  such,
1461       or by the range foo[1,9].
1462
1463       Some examples of range usage follow:
1464           foo[01-05] instead of foo01,foo02,foo03,foo04,foo05
1465           foo[7,9-10] instead of foo7,foo9,foo10
1466           foo[0-3] instead of foo0,foo1,foo2,foo3
1467
1468       As a reminder to the reader, some shells will interpret brackets ([ and
1469       ]) for pattern matching. Depending on your shell, it may  be  necessary
1470       to enclose ranged lists within quotes.
1471
1472       When  multiple  hosts  are specified by the user, a thread will be exe‐
1473       cuted for each host in parallel up to the configured fanout (which  can
1474       be  adjusted via the -F option). This will allow communication to large
1475       numbers of nodes far more quickly than if done in serial.
1476
1477       By default, standard output from each node  specified  will  be  output
1478       with the hostname prepended to each line. Although this output is read‐
1479       able in many situations, it may be difficult to read  in  other  situa‐
1480       tions.  For  example, output from multiple nodes may be mixed together.
1481       The -B and -C options can be used to change this default.
1482
1483       In-band IPMI Communication will be used when the  host  "localhost"  is
1484       specified.  This  allows  the  user  to add the localhost into the hos‐
1485       tranged output.
1486

GENERAL TROUBLESHOOTING

1488       Most often, IPMI problems are due to configuration problems.
1489
1490       IPMI over  LAN  problems  involve  a  misconfiguration  of  the  remote
1491       machine's  BMC.  Double check to make sure the following are configured
1492       properly in the remote machine's BMC: IP address, MAC  address,  subnet
1493       mask,  username,  user enablement, user privilege, password, LAN privi‐
1494       lege, LAN enablement, and allowed authentication type(s). For IPMI  2.0
1495       connections,  double  check  to make sure the cipher suite privilege(s)
1496       and K_g key are configured properly. The bmc-config(8) tool can be used
1497       to check and/or change these configuration settings.
1498
1499       Inband  IPMI  problems  are  typically  caused by improperly configured
1500       drivers or non-standard BMCs.
1501
1502       In addition to the troubleshooting tips below, please  see  WORKAROUNDS
1503       below to also if there are any vendor specific bugs that have been dis‐
1504       covered and worked around.
1505
1506       Listed below are many of the common issues  for  error  messages.   For
1507       additional  support, please e-mail the <freeipmi-users@gnu.org> mailing
1508       list.
1509
1510       "username invalid" - The username entered (or a NULL username  if  none
1511       was  entered)  is  not  available on the remote machine. It may also be
1512       possible the remote BMC's username configuration is incorrect.
1513
1514       "password invalid" - The password entered (or a NULL password  if  none
1515       was  entered)  is not correct. It may also be possible the password for
1516       the user is not correctly configured on the remote BMC.
1517
1518       "password verification timeout" - Password verification has timed  out.
1519       A  "password  invalid"  error  (described  above) or a generic "session
1520       timeout" (described below) occurred.  During this point in the protocol
1521       it cannot be differentiated which occurred.
1522
1523       "k_g  invalid"  -  The  K_g  key entered (or a NULL K_g key if none was
1524       entered) is not correct. It may also be possible the  K_g  key  is  not
1525       correctly configured on the remote BMC.
1526
1527       "privilege level insufficient" - An IPMI command requires a higher user
1528       privilege than the one authenticated with. Please try  to  authenticate
1529       with a higher privilege. This may require authenticating to a different
1530       user which has a higher maximum privilege.
1531
1532       "privilege level cannot be obtained for  this  user"  -  The  privilege
1533       level  you are attempting to authenticate with is higher than the maxi‐
1534       mum allowed for this user. Please try again with a lower privilege.  It
1535       may  also be possible the maximum privilege level allowed for a user is
1536       not configured properly on the remote BMC.
1537
1538       "authentication type unavailable for attempted privilege level"  -  The
1539       authentication  type you wish to authenticate with is not available for
1540       this privilege level. Please try again with an alternate authentication
1541       type  or  alternate privilege level. It may also be possible the avail‐
1542       able authentication types you can authenticate with are  not  correctly
1543       configured on the remote BMC.
1544
1545       "cipher suite id unavailable" - The cipher suite id you wish to authen‐
1546       ticate with is not available on the remote BMC. Please try  again  with
1547       an  alternate  cipher  suite  id. It may also be possible the available
1548       cipher suite ids are not correctly configured on the remote BMC.
1549
1550       "ipmi 2.0 unavailable" - IPMI 2.0 was  not  discovered  on  the  remote
1551       machine. Please try to use IPMI 1.5 instead.
1552
1553       "connection  timeout"  - Initial IPMI communication failed. A number of
1554       potential errors are possible, including an invalid hostname specified,
1555       an  IPMI  IP  address  cannot  be  resolved, IPMI is not enabled on the
1556       remote server, the network connection is bad, etc. Please  verify  con‐
1557       figuration and connectivity.
1558
1559       "session  timeout"  - The IPMI session has timed out. Please reconnect.
1560       If this error occurs often, you may wish to increase the retransmission
1561       timeout. Some remote BMCs are considerably slower than others.
1562
1563       "device  not  found"  - The specified device could not be found. Please
1564       check configuration or inputs and try again.
1565
1566       "driver timeout" - Communication with the driver or  device  has  timed
1567       out. Please try again.
1568
1569       "message  timeout"  - Communication with the driver or device has timed
1570       out. Please try again.
1571
1572       "BMC busy" - The BMC is currently busy. It may be  processing  informa‐
1573       tion  or have too many simultaneous sessions to manage. Please wait and
1574       try again.
1575
1576       "could not find inband device" - An inband device could not  be  found.
1577       Please  check configuration or specify specific device or driver on the
1578       command line.
1579
1580       "driver timeout" - The inband driver has timed out communicating to the
1581       local  BMC  or  service  processor. The BMC or service processor may be
1582       busy or (worst case) possibly non-functioning.
1583

WORKAROUNDS

1585       With so many different vendors implementing their own  IPMI  solutions,
1586       different  vendors  may implement their IPMI protocols incorrectly. The
1587       following describes a number of workarounds currently available to han‐
1588       dle  discovered compliance issues. When possible, workarounds have been
1589       implemented so they will be transparent to the user. However, some will
1590       require the user to specify a workaround be used via the -W option.
1591
1592       The hardware listed below may only indicate the hardware that a problem
1593       was discovered on. Newer versions of  hardware  may  fix  the  problems
1594       indicated  below.  Similar machines from vendors may or may not exhibit
1595       the same problems. Different vendors may license  their  firmware  from
1596       the  same IPMI firmware developer, so it may be worthwhile to try work‐
1597       arounds listed below even if your motherboard is not listed.
1598
1599       If you believe your hardware has an additional  compliance  issue  that
1600       needs a workaround to be implemented, please contact the FreeIPMI main‐
1601       tainers on <freeipmi-users@gnu.org> or <freeipmi-devel@gnu.org>.
1602
1603       assumeio - This workaround flag will assume inband interfaces  communi‐
1604       cate  with  system  I/O rather than being memory-mapped. This will work
1605       around systems that report invalid base addresses. Those  hitting  this
1606       issue  may see "device not supported" or "could not find inband device"
1607       errors.  Issue observed on HP ProLiant DL145 G1.
1608
1609       spinpoll - This workaround flag will inform some inband  drivers  (most
1610       notably  the  KCS driver) to spin while polling rather than putting the
1611       process to sleep. This may significantly improve the wall clock running
1612       time  of  tools because an operating system scheduler's granularity may
1613       be much larger than the time it takes to perform a single IPMI  message
1614       transaction.  However,  by spinning, your system may be performing less
1615       useful work by not contexting out the tool for a more useful task.
1616
1617       authcap - This workaround flag will  skip  early  checks  for  username
1618       capabilities,  authentication  capabilities,  and K_g support and allow
1619       IPMI authentication to succeed. It  works  around  multiple  issues  in
1620       which the remote system does not properly report username capabilities,
1621       authentication capabilities, or K_g status. Those  hitting  this  issue
1622       may  see  "username  invalid",  "authentication  type  unavailable  for
1623       attempted privilege level", or "k_g invalid" errors.  Issue observed on
1624       Asus  P5M2/P5MT-R/RS162-E4/RX4,  Intel  SR1520ML/X38ML,  and  Sun  Fire
1625       2200/4150/4450 with ELOM.
1626
1627       idzero - This workaround flag  will  allow  empty  session  IDs  to  be
1628       accepted by the client. It works around IPMI sessions that report empty
1629       session IDs to the client. Those hitting this issue  may  see  "session
1630       timeout" errors. Issue observed on Tyan S2882 with M3289 BMC.
1631
1632       unexpectedauth  -  This  workaround flag will allow unexpected non-null
1633       authcodes to be checked as though they were expected. It  works  around
1634       an  issue  when  packets contain non-null authentication data when they
1635       should be null due to disabled per-message authentication.  Those  hit‐
1636       ting  this  issue  may  see "session timeout" errors. Issue observed on
1637       Dell PowerEdge 2850,SC1425. Confirmed fixed on newer firmware.
1638
1639       forcepermsg - This workaround flag will force  per-message  authentica‐
1640       tion  to  be used no matter what is advertised by the remote system. It
1641       works around an issue when per-message authentication is advertised  as
1642       disabled on the remote system, but it is actually required for the pro‐
1643       tocol. Those hitting this  issue  may  see  "session  timeout"  errors.
1644       Issue observed on IBM eServer 325.
1645
1646       endianseq  -  This  workaround flag will flip the endian of the session
1647       sequence numbers to allow the session to continue  properly.  It  works
1648       around  IPMI  1.5  session  sequence numbers that are the wrong endian.
1649       Those hitting this  issue  may  see  "session  timeout"  errors.  Issue
1650       observed  on  some  Sun  ILOM  1.0/2.0  (depends  on  service processor
1651       endian).
1652
1653       noauthcodecheck - This workaround flag will tell FreeIPMI to not  check
1654       the  authentication  codes returned from IPMI 1.5 command responses. It
1655       works around systems to return  invalid  authentication  codes  due  to
1656       hashing  or  implementation  errors.  Users are cautioned on the use of
1657       this option, as it removes an authentication check verifying the valid‐
1658       ity of a packet. However, in most organizations, this is unlikely to be
1659       a security issue. Those hitting this issue may  see  "connection  time‐
1660       out",  "session  timeout",  or  "password verification timeout" errors.
1661       Issue observed on Xyratex FB-H8-SRAY.
1662
1663       intel20 - This workaround flag will work around several Intel IPMI  2.0
1664       authentication issues. The issues covered include padding of usernames,
1665       and password  truncation  if  the  authentication  algorithm  is  HMAC-
1666       MD5-128. Those hitting this issue may see "username invalid", "password
1667       invalid", or "k_g invalid" errors. Issue observed  on  Intel  SE7520AF2
1668       with Intel Server Management Module (Professional Edition).
1669
1670       supermicro20 - This workaround flag will work around several Supermicro
1671       IPMI 2.0  authentication  issues  on  motherboards  w/  Peppercon  IPMI
1672       firmware.  The issues covered include handling invalid length authenti‐
1673       cation codes. Those hitting  this  issue  may  see  "password  invalid"
1674       errors.   Issue  observed on Supermicro H8QME with SIMSO daughter card.
1675       Confirmed fixed on newerver firmware.
1676
1677       sun20 - This workaround flag will work work around several Sun IPMI 2.0
1678       authentication issues. The issues covered include invalid lengthed hash
1679       keys, improperly hashed keys, and invalid cipher suite  records.  Those
1680       hitting  this  issue  may see "password invalid" or "bmc error" errors.
1681       Issue observed on Sun Fire 4100/4200/4500 with ILOM.   This  workaround
1682       automatically includes the "opensesspriv" workaround.
1683
1684       opensesspriv - This workaround flag will slightly alter FreeIPMI's IPMI
1685       2.0 connection protocol to workaround an invalid hashing algorithm used
1686       by  the remote system. The privilege level sent during the Open Session
1687       stage of an IPMI 2.0 connection is used for hashing keys instead of the
1688       privilege  level  sent during the RAKP1 connection stage. Those hitting
1689       this issue may see "password invalid", "k_g invalid", or "bad  rmcpplus
1690       status  code"  errors.   Issue observed on Sun Fire 4100/4200/4500 with
1691       ILOM, Inventec 5441/Dell Xanadu II, Supermicro X8DTH, Supermicro X8DTG,
1692       Intel S5500WBV/Penguin Relion 700, Intel S2600JF/Appro 512X, and Quanta
1693       QSSC-S4R//Appro GB812X-CN. This workaround is  automatically  triggered
1694       with the "sun20" workaround.
1695
1696       integritycheckvalue  - This workaround flag will work around an invalid
1697       integrity check value during an IPMI  2.0  session  establishment  when
1698       using  Cipher Suite ID 0. The integrity check value should be 0 length,
1699       however the remote motherboard responds with a non-empty  field.  Those
1700       hitting  this  issue  may  see  "k_g invalid" errors. Issue observed on
1701       Supermicro X8DTG, Supermicro X8DTU, and Intel  S5500WBV/Penguin  Relion
1702       700, and Intel S2600JF/Appro 512X.
1703
1704       assumemaxsdrrecordcount  -  This  workaround will inform SDR reading to
1705       stop reading after a known maximum numer of SDR records have been read.
1706       This  will  work  around  systems that have mis-implemented SDR reading
1707       functions that. Those hitting this issue  may  see  "SDR  record  count
1708       invalid" errors. Issue observed on unspecified Inspur motherboard.
1709
1710       No IPMI 1.5 Support - Some motherboards that support IPMI 2.0 have been
1711       found to not support IPMI 1.5. Those hitting this issue may  see  "ipmi
1712       2.0  unavailable"  or  "connection  timeout"  errors. This issue can be
1713       worked around by using IPMI 2.0  instead  of  IPMI  1.5  by  specifying
1714       --driver-address=LAN_2_0. Issue observed on HP Proliant DL 145.
1715

DIAGNOSTICS

1717       Upon  successful  execution, exit status is 0. On error, exit status is
1718       1.
1719
1720       If multiple hosts are specified for communication, the exit status is 0
1721       if  and  only  if  all targets successfully execute. Otherwise the exit
1722       status is 1.
1723

KNOWN ISSUES

1725       On older operating systems, if you input your username,  password,  and
1726       other  potentially  security  relevant information on the command line,
1727       this information may be discovered by other users when using tools like
1728       the  ps(1) command or looking in the /proc file system. It is generally
1729       more secure to input password information with options like the  -P  or
1730       -K  options.  Configuring security relevant information in the FreeIPMI
1731       configuration file would also be an appropriate way to hide this infor‐
1732       mation.
1733
1734       In  order  to  prevent  brute force attacks, some BMCs will temporarily
1735       "lock up" after a number of remote authentication errors. You may  need
1736       to  wait awhile in order to this temporary "lock up" to pass before you
1737       may authenticate again.
1738

REPORTING BUGS

1740       Report bugs to <freeipmi-users@gnu.org> or <freeipmi-devel@gnu.org>.
1741
1743       Copyright © 2008-2012 FreeIPMI Core Team
1744
1745       This program is free software; you can redistribute it and/or modify it
1746       under  the  terms of the GNU General Public License as published by the
1747       Free Software Foundation; either version 3 of the License, or (at  your
1748       option) any later version.
1749

SEE ALSO

1751       freeipmi(7),  bmc-config(8),  bmc-device(8),  ipmi-pef-config(8), ipmi-
1752       raw(8)
1753
1754       http://www.gnu.org/software/freeipmi/
1755
1756
1757
1758IPMI OEM version 1.2.1            2017-03-22                       IPMI-OEM(8)