1g_density(1) GROMACS suite, VERSION 4.5 g_density(1)
2
3
4
6 g_density - calculates the density of the system
7
8 VERSION 4.5
9
11 g_density -f traj.xtc -n index.ndx -s topol.tpr -ei electrons.dat -o
12 density.xvg -[no]h -[no]version -nice int -b time -e time -dt time
13 -[no]w -xvg enum -d string -sl int -dens enum -ng int -[no]symm
14 -[no]center
15
17 Compute partial densities across the box, using an index file. Densi‐
18 ties in kg/m3, number densities or electron densities can be calcu‐
19 lated. For electron densities, a file describing the number of elec‐
20 trons for each type of atom should be provided using -ei. It should
21 look like:
22
23 2
24
25 atomname = nrelectrons
26
27 atomname = nrelectrons
28
29 The first line contains the number of lines to read from the file.
30 There should be one line for each unique atom name in your system. The
31 number of electrons for each atom is modified by its atomic partial
32 charge.
33
35 -f traj.xtc Input
36 Trajectory: xtc trr trj gro g96 pdb cpt
37
38 -n index.ndx Input, Opt.
39 Index file
40
41 -s topol.tpr Input
42 Run input file: tpr tpb tpa
43
44 -ei electrons.dat Input, Opt.
45 Generic data file
46
47 -o density.xvg Output
48 xvgr/xmgr file
49
50
52 -[no]hno
53 Print help info and quit
54
55 -[no]versionno
56 Print version info and quit
57
58 -nice int 19
59 Set the nicelevel
60
61 -b time 0
62 First frame (ps) to read from trajectory
63
64 -e time 0
65 Last frame (ps) to read from trajectory
66
67 -dt time 0
68 Only use frame when t MOD dt = first time (ps)
69
70 -[no]wno
71 View output xvg, xpm, eps and pdb files
72
73 -xvg enum xmgrace
74 xvg plot formatting: xmgrace, xmgr or none
75
76 -d string Z
77 Take the normal on the membrane in direction X, Y or Z.
78
79 -sl int 50
80 Divide the box in nr slices.
81
82 -dens enum mass
83 Density: mass, number, charge or electron
84
85 -ng int 1
86 Number of groups to compute densities of
87
88 -[no]symmno
89 Symmetrize the density along the axis, with respect to the center.
90 Useful for bilayers.
91
92 -[no]centerno
93 Shift the center of mass along the axis to zero. This means if your
94 axis is Z and your box is bX, bY, bZ, the center of mass will be at
95 bX/2, bY/2, 0.
96
97
99 - When calculating electron densities, atomnames are used instead of
100 types. This is bad.
101
102
104 gromacs(7)
105
106 More information about GROMACS is available at <http://www.gro‐
107 macs.org/>.
108
109
110
111 Thu 26 Aug 2010 g_density(1)