1RESTMBMASTER.CONF(5) Rest API Modbus master configuration RESTMBMASTER.CONF(5)
2
3
4
6 restmbmaster.conf — restmbmaster configuration file
7
9 restmbmaster uses very simple format of configuration file, each line
10 has following format:
11 key = value
12
13 In case the option does not support value the line format is:
14 key
15
17 debug Turns on debugging messages. Repeating the option increases ver‐
18 bosity.
19
20 connect = CONNECT_URI
21 Specifies the target Modbus bus to connect to. Supported for‐
22 mats:
23
24 tcp://HOSTNAME[:PORT]
25
26 Example: tcp://test.abc:1000
27
28 Default PORT: 502
29
30 rtu:DEVICEPATH[?baud=BAUDRATE]
31
32 Example: rtu:/dev/ttyS0?baud=9600
33
34 Default BAUDRATE: 115200
35
36 port = PORT
37 Specifies TCP port on which the webserver is listening and where
38 the Rest API is exposed.
39
40 dontkeep
41 Don't keep the connection open, connect only for the time when
42 command is processed.
43
45 Example Modbus TCP config:
46
47 connect = tcp://127.0.0.1:5020
48 port = 8080
49
50 Example Modbus RTU config:
51
52 connect = rtu:/dev/ttyUSB0?baud=9600
53 port = 8080
54
55 Example Modbus RTU config with debug messages verbosity:
56
57 connect = rtu:/dev/ttyUSB0?baud=9600
58 port = 8080
59 debug
60
62 restmbmaster(8),
63
65 Jiri Pirko is the original author and current maintainer of restmbmas‐
66 ter.