1NVME-CONNECT-ALL(1)               NVMe Manual              NVME-CONNECT-ALL(1)
2
3
4

NAME

6       nvme-connect-all - Discover and Connect to Fabrics controllers.
7

SYNOPSIS

9       nvme connect-all
10                       [--transport=<trtype>     | -t <trtype>]
11                       [--traddr=<traddr>        | -a <traddr>]
12                       [--trsvcid=<trsvcid>      | -s <trsvcid>]
13                       [--host-traddr=<traddr>   | -w <traddr>]
14                       [--hostnqn=<hostnqn>      | -q <hostnqn>]
15                       [--hostid=<hostid>        | -I <hostid>]
16                       [--raw=<filename>         | -r <filename>]
17                       [--keep-alive-tmo=<#>     | -k <#>]
18                       [--reconnect-delay=<#>    | -c <#>]
19                       [--ctrl-loss-tmo=<#>      | -l <#>]
20                       [--hdr_digest             | -g]
21                       [--data_digest            | -G]
22                       [--nr-io-queues=<#>       | -i <#>]
23                       [--nr-write-queues=<#>    | -W <#>]
24                       [--nr-poll-queues=<#>     | -P <#>]
25                       [--queue-size=<#>         | -Q <#>]
26

DESCRIPTION

28       Send one or more Discovery requests to a NVMe over Fabrics Discovery
29       Controller, and create controllers for the returned discovery records.
30
31       If no parameters are given, then nvme connect-all will attempt to find
32       a /etc/nvme/discovery.conf file to use to supply a list of connect-all
33       commands to run. If no /etc/nvme/discovery.conf file exists, the
34       command will quit with an error.
35
36       Otherwise a specific Discovery Controller should be specified using the
37       --transport, --traddr and if necessary the --trsvcid and a Diѕcovery
38       request will be sent to the specified Discovery Controller.
39
40       See the documentation for the nvme-discover(1) command for further
41       background.
42

OPTIONS

44       -t <trtype>, --transport=<trtype>
45           This field specifies the network fabric being used for a
46           NVMe-over-Fabrics network. Current string values include:
47
48           ┌──────┬────────────────────────────┐
49           │Value │ Definition                 │
50           ├──────┼────────────────────────────┤
51           │rdma  │ The network fabric is an   │
52           │      │ rdma network (RoCE, iWARP, │
53           │      │ Infiniband, basic rdma,    │
54           │      │ etc)                       │
55           ├──────┼────────────────────────────┤
56           │fc    │ WIP The network fabric is  │
57           │      │ a Fibre Channel network.   │
58           ├──────┼────────────────────────────┤
59           │loop  │ Connect to a NVMe over     │
60           │      │ Fabrics target on the      │
61           │      │ local host                 │
62           └──────┴────────────────────────────┘
63
64       -a <traddr>, --traddr=<traddr>
65           This field specifies the network address of the Discovery
66           Controller. For transports using IP addressing (e.g. rdma) this
67           should be an IP-based address (ex. IPv4).
68
69       -s <trsvcid>, --trsvcid=<trsvcid>
70           This field specifies the transport service id. For transports using
71           IP addressing (e.g. rdma) this field is the port number. By
72           default, the IP port number for the RDMA transport is 4420.
73
74       -w <traddr>, --host-traddr=<traddr>
75           This field specifies the network address used on the host to
76           connect to the Discovery Controller.
77
78       -q <hostnqn>, --hostnqn=<hostnqn>
79           Overrides the default Host NQN that identifies the NVMe Host. If
80           this option is not specified, the default is read from
81           /etc/nvme/hostnqn first. If that does not exist, the autogenerated
82           NQN value from the NVMe Host kernel module is used next. The Host
83           NQN uniquely identifies the NVMe Host, and may be used by the the
84           Discovery Controller to control what NVMe Target resources are
85           allocated to the NVMe Host for a connection.
86
87       -I <hostid>, --hostid=<hostid>
88           UUID(Universally Unique Identifier) to be discovered which should
89           be formatted.
90
91       -r <filename>, --raw=<filename>
92           This field will take the output of the nvme connect-all command and
93           dump it to a raw binary file. By default nvme connect-all will dump
94           the output to stdout.
95
96       -k <#>, --keep-alive-tmo=<#>
97           Overrides the default keep alive timeout (in seconds).
98
99       -c <#>, --reconnect-delay=<#>
100           Overrides the default delay (in seconds) before reconnect is
101           attempted after a connect loss.
102
103       -l <#>, --ctrl-loss-tmo=<#>
104           Overrides the default controller loss timeout period (in seconds).
105
106       -g, --hdr_digest
107           Generates/verifies header digest (TCP).
108
109       -G, --data_digest
110           Generates/verifies data digest (TCP).
111
112       -i <#>, --nr-io-queues=<#>
113           Overrides the default number of I/O queues create by the driver.
114
115       -W <#>, --nr-write-queues=<#>
116           Adds additional queues that will be used for write I/O.
117
118       -P <#>, --nr-poll-queues=<#>
119           Adds additional queues that will be used for polling latency
120           sensitive I/O.
121
122       -Q <#>, --queue-size=<#>
123           Overrides the default number of elements in the I/O queues created
124           by the driver.
125

EXAMPLES

127       ·   Connect to all records returned by the Discover Controller with IP4
128           address 192.168.1.3 for all resources allocated for NVMe Host name
129           host1-rogue-nqn on the RDMA network. Port 4420 is used by default:
130
131               # nvme connect-all --transport=rdma --traddr=192.168.1.3 \
132               --hostnqn=host1-rogue-nqn
133
134       ·   Issue a nvme connect-all command using a /etc/nvme/discovery.conf
135           file:
136
137               # Machine default 'nvme discover' commands.  Query the
138               # Discovery Controller's two ports (some resources may only
139               # be accessible on a single port).  Note an official
140               # nqn (Host) name defined in the NVMe specification is being used
141               # in this example.
142               -t rdma -a 192.168.69.33 -s 4420 -q nqn.2014-08.com.example:nvme:nvm-subsystem-sn-d78432
143               -t rdma -a 192.168.1.4   -s 4420 -q nqn.2014-08.com.example:nvme:nvm-subsystem-sn-d78432
144
145               At the prompt type "nvme connect-all".
146

SEE ALSO

148       nvme-discover(1) nvme-connect(1)
149

NVME

151       Part of the nvme-user suite
152
153
154
155NVMe                              04/08/2019               NVME-CONNECT-ALL(1)
Impressum